Do you have a question about the Sartorius Research RC 210D and is the answer not in the manual?

Sartorius Research RC 210D Specifications

General IconGeneral
BrandSartorius
ModelResearch RC 210D
CategoryScales
LanguageEnglish

Summary

General Information

Service Prerequisites

Prerequisites for working on Sartorius high-resolution balances, including experience and special tools.

Work Area & Environment

Notes on the optimum work area for balance testing and adjustments, focusing on ambient conditions.

Measuring and Test Equipment

Information on essential measuring and test equipment, emphasizing the importance of calibrated weights.

Balance Overview and Tools

Service Tools and Accompanying Literature

List of special tools, equipment, and supporting literature for Sartorius RC/MC Balances.

Key Functions

Description of key functions for MC and RC balance models, detailing button operations.

Brief Operation - Settings

Setting ID Code, Time, and Date

Instructions for setting the ID code, time, and date on the balance for GLP/GMP records.

Time Setting

Procedure for setting the time, including 12-hour and 24-hour display options.

Date Setting

Instructions for setting the date, separating day, month, and year with a dot.

Displaying Hardware and Software Version

How to check the balance's hardware generation and software version via the display.

Balance Operating Menu

Accessing Menu and Setting Code

Steps to access the operating menu, select codes, and set a menu code for balance configuration.

Metrological Specifications Prerequisites

Prerequisites for Metrological Checks

Conditions to meet before checking specifications, including installation and warm-up.

Place of Installation

Requirements for the balance installation environment: temperature, surface, and drafts.

Test Weights for Testing

Guidelines for using calibrated weights for testing and adjusting the balance span.

Standard Testing Procedures

Checking Reproducibility (Standard Deviation)

Procedure for checking reproducibility using test weights and evaluating results.

Checking Off-center Loading Tolerances

Procedure for testing off-center loading tolerances with specific test weights.

Checking Internal Span Adjustment

Procedure for checking and evaluating internal span adjustment using test weights.

Linearity Testing

Detailed steps for checking linearity, calculating errors, and evaluating results against tolerances.

Balance Adjustment Procedures

Adjustment Sequence and Preparation

Sequence of adjustments (reproducibility, off-center load, linearity, span) and preparation steps.

BPI Mode Setup

Procedure to set RC and MC models to BPI mode for adjustments.

Off-Center Load Adjustment

Required tools, weights, and procedures for coarse and fine off-center load adjustment.

Linearity Adjustment Methods

Methods for external and internal linearity adjustment using service manual or software.

Span Adjustment Methods

Procedures for external span adjustment and overwriting internal weights.

Internal and Automatic Adjustment

Procedures for internal adjustment and automatic isoCAL function.

Balance Housing and Component Handling

Opening the Balance Housing

Steps to disconnect power and remove the balance housing.

Removing PCBs and Enclosure

Procedure to unplug connectors, remove PCBs, and lift off enclosure frame parts.

Installing PCBs and Enclosure

Steps to install PCBs, connect cables, and reassemble the balance housing.

Closing the Balance Housing

Procedure to replace and secure the top part of the balance housing.

Draft Shield Exchange

Removing the Draft Shield

Steps to disconnect power, remove draft shield components, and lift off the draft shield.

Installing the Draft Shield

Procedure to install the new draft shield, route cables, and replace components.

Weighing System and Calibration System Cleaning

Cleaning the Weighing System

Procedure for cleaning the weighing system if reproducibility is poor.

Exposing and Cleaning Calibration System

Steps to expose and clean the calibration/adjustment weight operating system.

Weight Maintenance and Electronics Repair

Checking and Replacing Weights

Procedure to check weights for dirt, replace them, and reassemble the balance.

Exchanging Display, Digital, and Analog PCBs

Steps to exchange the display, digital, and analog PCBs.

Component Diagrams and Troubleshooting

Exploded-View Diagrams

Diagrams showing exploded views of balance components and electronics.

Troubleshooting Guide (Software and Hardware Errors)

Guide listing software and hardware error codes, their meanings, and solutions.

Operating Menu and Calibration Protocol

Quick-Reference Guide to Balance Menu

Menu structure and code settings for RC and MC balance models.

Calibration Protocol Procedures

Procedures for calibrating reproducibility, kennwert, linearity, and off-center load.