When servicing the meter, use only specified replacement parts.
Use caution when working with voltage above 30V ac rms, 42V peak, or 60V dc. Such voltages pose a shock hazard.
When using the probes, keep your fingers behind the finger guards on the probes.
Connect the common test lead before you connect the live test lead. When you disconnect test leads, disconnect the live test lead first.
Remove the test leads from the meter before you open the battery cover or the case.
Do not operate the meter with the battery cover or portions of the case removed or loosened.
To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the low battery
indicator ( ) appears.
Do not use the meter in a manner not specified by this manual or the safety features provided by the meter be impaired.
Adhere to local and national safety codes. Individual protective equipment must be used to prevent shock and arc blast injury where
hazardous live conductors are exposed.
To void electric shock and personal injury, do not touch any naked conductor with hand or skin; and do not ground yourself while using this
meter.
Do not use the meter if the meter, a test lead or your hand is wet.
Remaining endangerment:
When an input terminal is connected to dangerous live potential it is to be noted that this potential can occur at all other terminals!
CAT II - Measurement Category II is for measurements performed on circuits directly connected to low voltage installation. ( Examples are
measurements on household appliances, portable tools and similar equipments. )
Do not use the meter for measurements within Measurement Categories III and IV.
DY03005 Users Manual