EasyManua.ls Logo

Saturn KDB - 201 GOM - 4.10 High Limit Fuse (Fuse Type); High Limit Fuse Function

Saturn KDB - 201 GOM
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KDB-GOM
Series
- 21 -
4.10 High Limit Fuse (Fuse Type)
Function
- In case of abnormal overheat of heat exchanger, the temperature of sensor
part will be more than 195
, high limit fuse will cut off the power of
modulating gas control valve to close the modulating gas control valve and
secure the safety.
- Check lamp will on in the room thermostat and failure code # 03 will be
indicated.
Type Fuse Type
Structure
Operation Temp. OFF point: 195
Electric Rating
Resistance
61.1
Ω
at 20