EasyManua.ls Logo

Saturn KDB - 201 GOM - Ignition Transformer

Saturn KDB - 201 GOM
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KDB-GOM
Series
- 88 -
No 10 Part name Ignition transformer
Replacement steps
Disassembly
Unplug the boiler from the electric outlet.
Open the front cover.
Separate the two high voltage cables of the ignition transformer connected to the electrode from the electrode.
Separate the ignition transformer power cord jack.
Separate the ignition transformer by unscrewing the two screws.
Assembly
Screw the two screws fixing the ignition transformer.
Connect the ignition transformer power cord jack.
Connect the ignition transformer’s two high voltage cords to the electrode.
Close the boiler’s front cover.
Plug the boiler into the electric outlet.
Caution
1. Make sure fixation is done correctly.
2. Check the connection of the connection jack.

Table of Contents

Related product manuals