KDB-GOM
Series
- 87 -
No 9 Part name Heating strainer
Replacement steps
Disassembly
󰼿Unplug the boiler from the electric outlet.
󰼿Open the front cover.
󰼿Release the heating water inside the boiler by unscrewing the drain screw below the circulator pump.
󰼿Separate the strainer by separating the
shaped lock.
󰼿Separate the hot water heat exchanger from the strainer by removing the connecting clip.
󰼿Separate the expansion tank from the strainer by removing the connecting connection.
Assembly
󰼿Fix the strainer to the boiler.
󰼿Fix the hot water heat exchanger by inserting the connecting clip.
󰼿Fix the expansion tank and the strainer by inserting the connecting connection.
󰼿Fix the strainer by screwing the 3 screws under the front cover (check the packing status between the strainer
and return inlet connection).
󰼿Fix the strainer and the
shaped lock.
󰼿Screw the drain screw under the circulator pump.
󰼿Unplug the power cord and after water replenishment, check for water leak
󰼿If everything is fine, close the front cover.
󰼿Plug the boiler into the electric outlet.
Caution
Check for water leak after assembly.