KDB-GOM
Series
- 7 -
2.3 Schematic Diagram of Operating
2.3.1 Schematic Diagram at the Heating Water Supply
High Limit Fuse
Fan Assembly
Heating Temperature
Sensor
Hot Water Flow Switch
Modulating
Gas Control Valve
Expansion Tank
Air Pressure Switch
Nozzle Holder Assembly
Burner Assembly
Flame Detector
Electrode
High Limit Sensor
Main Heat Exchanger
Exhaust Duct
3-Way Valve
Gas Inlet
Domestic Water Outlet
Tap Water Inlet
Heating Return
Heating Supply
Heating Strainer
Circulator Pump
Flue Exhaust
Heating Flow Sensor
Combustion Air Inlet
Domestic Water
Heat Exchanger
Circulator Pump
Main Heat Exchanger
3-Way Valve
Heating Supply
Heating Strainer
Heating Return
Room Heating(Heating Coil, Radiator)