SAFETY PRECAUTIONS
USE A METAL CONTAINER WITH A TIGHT FITTING LID TO DISPOSE OF ASHES.
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL
LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR “FRESHEN UP” A FIRE IN THIS
STOVE. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE STOVE WHILE IT IS IN
USE.
DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA
OR ENGINE OIL.
THIS STOVE IS HOT WHILE IN OPERATION. DO NOT TOUCH, AND KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. USE
GLOVES WHEN STOKING THE FIRE.
DO NOT CONNECT THIS STOVE TO A CHIMNEY FLUE CONNECTED TO ANOTHER
STOVE OR APPLIANCE.
DO NOT CONNECT TO ANY AIR-DISTRIBUTION DUCT OR SYSTEM.
BE SURE TO ALLOW AN ADEQUATE SOURCE OF FRESH AIR INTO THE ROOM
WHERE THE STOVE IS OPERATING (SEE ROOM VENTILATION PAGE 16 AND
COMBUSTION AIR SUPPLY PAGE 17).
DO NOT OPERATE THE STOVE WITHOUT THE FIREBOX BAFFLE PLATES PROPERLY
INSTALLED.
BUILD FIRES DIRECTLY UPON THE HEARTH INSIDE THE STOVE. DO NOT USE
GRATES, IRONS, OR ANY OTHER METHOD TO ELEVATE THE FIRE.
THE SCAN STOVES ARE NOT USABLE FOR FIREPLACE INSTALLATION.
FOR USA ONLY:
WHEN INSTALLING IN A MOBILE, THIS APPLIANCE MUST BE BOLTED TO THE
FLOOR, HAVE OUTSIDE AIR SOURCE FOR COMBUSTION, AND NOT BE INSTALLED
IN THE BEDROOM (PER H.U.D. REQUIREMENTS). CHECK WITH LOCAL BUILDING
OFFICIALS.
FOR CANADA ONLY:
DO NOT INSTALL IN A MOBILE HOME