EasyManuals Logo

Scania DC13 076 User Manual

Scania DC13 076
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
OPM 200 en-GB 56
©
Scania CV AB 2014, Sweden
Fuel system
Fuel system
Sulphur content in fuel and its effect on oil
change interval
A sulphur content of 0-500 ppm in the fuel
gives an oil change interval of up to 500
hours.
Note:
More than 15 ppm sulphur content must only be
used where Stage 3A/Tier 3 or less restrictive
emission laws apply.
General information on the
XPI fuel system
IMPORTANT!
The fuel system is very sensitive to dirt. It is
therefore important that everything is as clean as
possible when work is carried out on the fuel sys-
tem.
Do not use compressed air to blow fuel system
components clean as this could cause dirt parti-
cles to penetrate the system.
Use lint-free rags for cleaning to prevent lint
from entering sensitive parts.
Clean the tools before use.
Do not use worn chrome-plated tools as chrome
flakes may come off.
Plug or tape connections on components which
are removed.
Checking fuel level
Daily
Check the fuel level and top up with fuel as
necessary.
Note:
The fuel system must be bled if the tank has been
run dry. Refer to the Bleeding the fuel system
section.
Property of American Airlines

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Scania DC13 076 and is the answer not in the manual?

Scania DC13 076 Specifications

General IconGeneral
BrandScania
ModelDC13 076
CategoryEngine
LanguageEnglish

Related product manuals