- 22 -
User Manual | 05.2015 | v01
www.schaererusa.com Error Messages
Display Message Cause Remedy
selection locked
over curr. brewmotor
The brew unit has too much electricity (over
4A).
Brew unit is jammed.
Call for service.
select product
water ow error
No water connection.
Defective pump (pump pressure < 7.5 bar).
Brew unit blocked.
Water system blocked.
Grinder mixture too ne.
PCB - owmeter incorrectly connected.
Electrical problem.
Open the shut-off valve and press the beverage
button again.
Check the brew unit.
Check the grinder mixture.
If the message persists, call for service.
select product
over temp. brewwater
Electrical problem between the sensor and
the PCB.
Temperature sensor defective.
Call for service.
select product
over temp. tea
Electrical problem between the sensor and
the PCB.
Temperature sensor defective.
Call for service.
select product
over temp. steam
Electrical problem between the sensor and
the PCB.
Temperature sensor defective.
Call for service.
selection locked
heating coffee water
The temperature is 10 °C below the
programmed temperature.
Beverage output is blocked!
Wait until the target temperature has been
reached.
If the message persists, call for service.
selection locked
heating hot water
The temperature is 10 °C below the
programmed temperature.
Beverage output is blocked!
Wait until the target temperature has been
reached.
If the message persists, call for service.
selection locked
heating steam
The temperature is 10 °C below the
programmed temperature.
Beverages cannot be dispensed when the
temperature is below 110 °C.
Wait until the target temperature has been
reached.
If the message persists, call for service.
select product
timeout coffee heater
The programmed temperature of the coffee
water boiler was not reached within 4 minutes
after the machine was switched on.
Beverage output is blocked!
Switch the machine off and then back on.
If the message persists, call for service.
select product
timeout HW heater
The programmed temperature of the hot water
boiler was not reached within 4 minutes after
the machine was switched on.
Hot water beverage output is blocked!
Switch the machine off and then back on.
If the message persists, call for service.
select product
timeout steam heater
The programmed temperature of the steam
boiler was not reached within 4 minutes after
the machine was switched on.
Steam output is blocked!
Switch the machine off and then back on.
If the message persists, call for service.
selection locked
coffee sensor def.
Electrical problem between the sensor and
the PCB.
Temperature sensor defective.
Beverage output is blocked!
Call for service.
selection locked
HW sensor def.
Electrical problem between the sensor and
the PCB.
Temperature sensor defective.
Beverage output is blocked!
Call for service.

Other manuals for Schaerer Art 1x7 FS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schaerer Art 1x7 FS and is the answer not in the manual?

Schaerer Art 1x7 FS Specifications

General IconGeneral
BrandSchaerer
ModelArt 1x7 FS
CategoryCoffee Maker
LanguageEnglish

Related product manuals