Operating Instruction Manual
Elektroblock EBL 263-5 Art no 911.056 page 1 / 10
Note: this operating instruction manual is intended for the customer and has to be supplied with the device
Schaudt GmbH, Elektrotechnik & Apparatebau, Daimlerstraße 5, D-88677 Markdorf, Tel +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt-gmbh.de 18.05.2004
Contents
1. Description
2. Safety Information
3. Operating Instructions
4. Transport, Storage, Installation
5. Electrical Installation
6. Power-Up, Shut-Down, Maintenance
7. Malfunction
8. Enclosure
1. Description
The Elektroblock EBL 263-5 is an energy management system for motor homes. It is a combination of
a battery charger, a 12V distribution box and a control and switch panel.
It contains the charging module LA 204, a battery monitor, the complete 12V distribution, fuse-protected
12V circuits and additional control and monitoring devices.
The controls and switches on the front panel, control the living-area functions of the motor home and
indicate certain values like voltages or filling levels.
Tank sensors are necessary to measure the filling levels of the water tanks. Please do order separately.
Note: The EBL 263-5 is not
suitable for filling level measurement of metal water tanks.
1.1 Suitable Accessories
rod tank sensors 2 rod tank sensors, 2 sensor cables 4 x 0.5
2 seal rings art no 126.007, 2 check nuts art no 102.106
or tank sensors 8 tank sensors, art no 933.662, 2 sensor cables 4 x 0.5
1.2 Technical Data
1.2.1 General Data
sizes front panel: 290 x 155
cabinet: 275 x 130 x 173 (W x H x D in mm)
weight 4.4 kg
cabinet PA (Polyamide), Gentian blue RAL 5010
front panel aluminium, powder painted, white aluminium RAL 9006
1.2.2 Electrical Data
mains supply * 230V (+ 6 / - 10%), 50Hz, safety class 1
current draw * 230VA
suitable batteries * 6 cell lead-acid or lead-gel batteries, from 35Ah
quiescent current * max 0.6mA
off living-area battery
load current of alternator's * approx 0.3A
D+ output by EBL
permissible load on * maximum current draw up to the fuse rating of each output;
12V outputs see enclosed block diagram.
Question and Answer IconNeed help?

Do you have a question about the Schaudt EBL 263-5 and is the answer not in the manual?

Schaudt EBL 263-5 Specifications

General IconGeneral
Output Voltage12V DC
Max Output Current25 A
Charging Current18A
Power300 W
Battery TypeLead-acid
ProtectionOverload, short circuit

Summary

Product Description and Technical Specifications

Suitable Accessories

Lists recommended accessories for tank level measurement, including rod tank sensors.

General and Electrical Data

Details physical dimensions, weight, mains supply, battery requirements, and current draw.

Safety Information and Operating Instructions

Safety Information

Covers essential safety regulations, prohibitions on alterations, and required qualifications for installation.

Operating Instructions: Controls and Indicators

Explains how to operate the 12V supply, check battery voltage, and provides important cautions.

Functionality and Indicators

LED Battery Indicator Evaluation

Describes how LED indicators reflect battery status under different conditions and loads.

Water Pump Power Control

Instructions for switching the water pump on/off and notes on its power consumption.

Additional Features and System Components

Waste Water Heater and Tank Level Inquiry

Details control for waste water heater and inquiry of fresh/waste water tank levels.

Battery-Type Selector Switch

Explains the function and importance of setting the battery-type selector switch correctly.

Fuses, Relays, and Battery Monitoring

12V Fuses and Circuit Protection

Describes the PolySwitch fuses, their function, and troubleshooting for blown fuses.

Relay Functions

Explains the operation of main-switch, battery cut-off, and water pump relays.

System Monitoring and Installation Guidelines

Battery Monitor and System Operation

Details the battery monitor's voltage comparison and automatic shut-down functions.

Transport, Storage, and Installation

Provides guidelines for transporting, storing, and installing the Elektroblock unit.

Electrical Installation and Connections

Electrical Installation Requirements

Emphasizes qualified personnel, battery connection, and safety precautions for electrical installation.

230V Mains and Battery Connections

Details connection procedures for 230V mains supply and battery terminals, including fuse ratings.

System Operation, Maintenance, and Troubleshooting

12V Consumers and Water Tank Connections

Explains connection of 12V consumers and water tanks, and their protection requirements.

Operation, Shut-Down, Maintenance, and Malfunctions

Covers initial operation, shutdown procedures, maintenance, and troubleshooting common malfunctions.

Enclosure and Declarations

Enclosure Contents and Delivery

Lists enclosures belonging to the manual and delivery requirements.

EC Declaration of Conformity

Certifies compliance with relevant EC low-voltage and EMC directives and applied standards.