Operating Instructions Electroblock EBL 211
12
Date: 22.01.2016 9110476 BA / EN
Starter battery
Charge current trickle charge max. 2 A
Charging voltage typ. U
Wbat
-- 0 , 2 V
New charge cycle, for battery voltage < 13.7 V
switchover to main charging with approx. 5 seconds delay
Main c harge
I
Full charge
Uo
Trickle charge
U
16 h for lead-gel
4hforAGM
Time
Lead-gel:14.4V
AGM: 14.7 V
U
charge
V
Lead-gel:13.7V
AGM: 13.7V
Fig. 3 Charging voltage with EBL 21 1 electroblock
I Main charge with maximum 18 A charging current, electronically limi-
ted, up to final charging voltage. Start of charge also for completely
discharged batteries.
Uo Automatic switchover to full charge with constant 14.4 V (lead-gel) or
14.7 V (AGM). The duration of the full charge phase is based on the
battery type and is set on the device.
U Automatic changeover to compensation charge with constant 13.7 V. In
the compensation charge phase, the voltage at the output of the char-
ging module is constant.
Start of a new charging cycle by switching over to main charge, if the battery
voltage falls below 13.7 V for more than 5 seconds when loaded. Start of
charge also for completely discharged batteries. The internal charge module
can also be operated without leisure battery.
6 Maintenance
The electroblock requires no maintenance.
Clean the electroblock with a soft, slightly damp cloth and mild detergent.
Never use spirit, thinners or similar substances. Do not allow liquids to enter
the electroblock.
No part of this manual may be reproduced, translated or copied without ex-
press written permission.
Battery charging of the
starter battery
IUoU curve
Cleaning
E