Instruction Manual for Electroblock EBL 30 / EBL 30 with OVP
9
Date: 15.10.2018
8110305 BA / EN
4.2 Additional functions
This relay supplies the AES/compressor refrigerator with power from the
starter battery when the vehicle engine is running and the D+ connection is
live. An AES refrigerator is powered by the living area battery when the vehi-
cle engine is not running.
This feature provides an automatic max. 6 A float charge for the starter bat-
tery when the 230V mains is connected to the electroblock.
The electroblock is isolated from the mains within 10ms in the event of a
voltage greater than 265 V
eff. The electroblock switches itself back on
again by itself after the mains voltage has attained the normal value.
5 Technical details
5.1 Mechanical details
130 x 275 x 170 (H x W x D in mm), including attachment feet
2.0 kg
PA (polyamide), gentian blue (RAL 5010)
Aluminium, powder coated, light grey (RAL 7035)
5.2 Electrical details
230V AC 10%, 47 -- 63 Hz sinusoidal, protection class I
1.9 A
6-cell lead-gel or AGM batteries, 55 Ah and above
Dependent on the control panel: approx. 5 -- 20 mA, plus consumption of
controller electronics of refrigerator
Conditions for the measurement:
F approx. 10 minutes after disconnection from the mains
F 12.6 V battery voltage
F Battery alarm OFF
F Battery cut-off switch ON
F Lighting for operator and control panel OFF
F All consumers switched off
F 12V main switch off
Loading of D+ output of the alternator by the electroblock approx. 0.5 mA
without current consumption on D+ point
12V outputs A maximum of 90% of the nominal
current of the relevant fuse may be
drawn.
Frost protection valve output max. 0.1 A
D+ point 1 A for fusing D+ input with 2 A
Automatic switch
function for
AES/compressor
refrigerator
Mains charging
starter battery
Overvoltage protection
fortheEBL30withOVP
Dimensions
Weight
Casing
Front
Mains connection
Current consumption
Suitable batteries
Standby current from
leisure battery
D+ loading
Current-carrying
capacity