Domotique embarquée
Embedded home automation
P.11
Domotique embarquée
Embedded home automation
Troubleshooting Guide
Observed dysfunction Troubleshooting instructions
The outputs do not work
1. Check the protection (fuse or circuit breaker) on the power input
2. Check the power of the uses (5 A max per output)
3. Check the voltage on the power connector
4. Check the module alarm clock (ashing green led)
5. Check the switch conguration
6. Check the range of the switch(es)
Some outputs work
1. Check the power of the uses (5 A max per output)
2. Check the adequacy between connection and conguration
3. Check that there is not twice the same aection
(living room lighting on two dierent exits for example)
4. Check that there is ON and OFF parameterized.
No blinking green LED
1. Check the protection (fuse or circuit breaker) on the power input
2. Check the power of the uses (5 A max per output)
3. Check the alarm clock of the module (ashing green LED)
4. Change the module if the checks from 1 to 3 are in accordance
The module does not appear on the network
(if presence of a NAVICOLOR)
1. Check CAN cable
2. Check CAN 120Ω BUS termination presence at each end of the CAN Network
3. Check of the alarm clock of the module (ashing green led)
4. Stop and restart the installation
Multi SFSP display at power on
(if multiple modules present in the installation)
Multiple modules have been detected with the same coding number
1. Check and dierentiate the modules using the coding entry.
2. Module 1 being the one with coding entry 1 ° etc ...