EasyManua.ls Logo

Scheiber LIGHT AIR SWITCH 43.00009.10 - User Manual

Scheiber LIGHT AIR SWITCH 43.00009.10
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Domotique embarquée
Embedded home automation
P. 1
Domotique embarquée
Embedded home automation
Acknowledgement...................................................P.2
Safety Warnings.........................................................P.2
Equipment description...........................................P.2
Accessories / Associated references.................P.2
Technical characteristics........................................P.3
Connectors.................................................................P.4
Set-up............................................................................P.5
Wiring...........................................................................P.5
Pairing...........................................................................P.7
Conguration.............................................................P.8
Troubleshooting guide...........................................P.11
Terms and conditions.............................................P.12
Warranty terms & after-sales..............................P.12
User Manuel & Troubleshooting Guide
LIGHT AIR SWITCH
Ref : 43.00009.10

Questions and Answers

  • S
    shammondAug 4, 2025
    Why do the outputs not work on my Scheiber Switch?
    • G
      gregoryhopkinsAug 4, 2025
      If the outputs on your Scheiber Switch are not working, several factors could be the cause. Here's what you should check: * Verify the protection (fuse or circuit breaker) on the power input. * Ensure the power usage does not exceed 5A per output. * Confirm the voltage on the power connector. * Check the module alarm clock (look for a flashing green LED). * Review the switch configuration. * Assess the switch range.
  • J
    Justin DavisAug 10, 2025
    What to do if the Scheiber Switch module does not appear on the network?
    • B
      bcoleAug 10, 2025
      If your Scheiber Switch module isn't showing up on the network, especially with a NAVICOLOR system, try these steps: 1. Inspect the CAN cable for any issues. 2. Confirm the presence of CAN 120? BUS termination at both ends of the CAN Network. 3. Examine the module's alarm clock, looking for a flashing green LED. 4. Try stopping and restarting the entire installation.
  • D
    Donna MillerAug 15, 2025
    How to fix some outputs working on Scheiber Switch?
    • J
      Justin AdamsAug 15, 2025
      If some outputs on your Scheiber Switch are working while others aren't, consider these checks: * Make sure the power usage is within the limit (5 A max per output). * Ensure the connection and configuration are correctly matched. * Verify that the same function isn't assigned to multiple outputs (e.g., living room lighting on two different exits). * Confirm that both ON and OFF states are properly parameterized.
  • E
    Evan HughesAug 21, 2025
    What does Multi SFSP display mean on Scheiber Switch?
    • J
      Joe NewmanAug 21, 2025
      If you see a 'Multi SFSP' display when powering on your Scheiber Switch (with multiple modules), it means multiple modules have been detected with the same coding number. To resolve this, check and differentiate the modules using the coding entry. Module 1 should have coding entry 1, and so on.
  • K
    Kevin WrightAug 27, 2025
    What to do if there is no blinking green LED on Scheiber Switch?
    • C
      cmartinAug 28, 2025
      If there is no blinking green LED on your Scheiber Switch, you should: 1. Check the protection (fuse or circuit breaker) on the power input. 2. Check the power of the uses (5 A max per output). 3. Check the alarm clock of the module (flashing green LED). 4. If the checks from 1 to 3 are in accordance - change the module.

Summary

Safety Warnings

General Safety Instructions

Covers warnings about disassembly, impact, and unpacking procedures.

Technical Specifications

Lighting Control Module Specifications

Technical details for the lighting control module, including power, inputs, and outputs.

2.4 GHz Antenna Module Specifications

Technical details for the 2.4 GHz antenna module, covering power supply and radio standards.

Switch Specifications

Technical details for the wireless switches, including power source and number of buttons.

Connectors

Installation Instructions

Advanced Wiring Examples

Pairing Switches to Outputs

Pairing Methods

Explains pairing switches with one or two buttons for ON/OFF and dimming control.

Configuration

Troubleshooting Guide

Outputs Not Working

Checks for when none of the outputs are functioning, covering power and configuration.

Some Outputs Working

Checks for when only some outputs are functioning, focusing on connections and configuration.

No Blinking Green LED

Troubleshooting steps when the green LED is not blinking, indicating a potential module issue.

Module Not Appearing on Network

Steps to resolve issues with modules not showing on the network, checking cables and termination.

Multi SFSP Display Issue

Troubleshooting when multiple modules show the same coding number, requiring differentiation.

Scheiber LIGHT AIR SWITCH 43.00009.10 Specifications

General IconGeneral
BrandScheiber
ModelLIGHT AIR SWITCH 43.00009.10
CategorySwitch
LanguageEnglish