4. Parameters
The controller allows the user to change some parameters as those that determines the operation of the
compressor,. The default values for the adjustable parameters are listed in the table on the next page.
The parameters can only be adjusted when the compressor is stopped.
1. To enter the parameter programming mode, simultaneously press and hold the PROGR button for 3
seconds. After 3 seconds, the code of the first parameter, P01, will appear on the display.
2. To scroll up or down the parameter list, press ON or OFF buttons respectively.
3. To view the current value of a parameter, press the PROG button again.
4. To edit the displayed value, press ON (increase) or OFF (decrease) buttons. The chosen value flashes if
the min or max available value is reached. Once the desired value has been entered, press PROG button
to store the value and to return to the parameter list.
5. To edit the value of another parameter, scroll up or down the list until the parameter symbol of the desired
parameter is displayed, and repeat step 4.
6. To exit the programming mode after adjusting all the desired parameters, press and hold the PROG button
for about 3 seconds. At this stage, the OFF or “---” message appears on the display and all the changes
made to the parameters are activated.
Note! If no button is pressed for 60 seconds during the programming procedure, the controller will
automatically exit the programming mode, switch back to OFF and store all the changes.