STEUEREINHEIT AIRBASIC 2 –GEBRAUCHSANWEISUNGEN
AIRBASIC 2 CONTROLLER – USER MANUAL
40
P19
Air filter maintenance pre-alarm
hours
h
100 9900
1500 1500
P20
Oil filter maintenance pre-alarm
hours
h
100 9900
3000 1500
P21
Separator filter maintenance pre-
alarm hours
h
100 9900
3000 1500
P22 Oil maintenance pre-alarm hours h
100 9900
3000 1500
P23
General maintenance pre-alarm
hours
h
100 9900
500 500
P24 Measurement unit for pressure / 0 - 1 0 0
P25 Measurement unit for temperature / 0 - 1 0 0
P26 Automatic restart status / 0 - 1 0 0
P27 Alarm relay function / 0 - 2 0 0
P28 Output OUT1 function / 0 - 2 0 0
P29 Input IN5 function / 0 - 2 0 0
P30 Profile selection / 0 - 1 0 0
P31 Compressor address / 1 - 30 1 1
P32
(4)
Input load/unload remote function
enable
/ 0 - 1 1 1
1
From firmware revision 0.11 this value has been changed from 9 to 8 bar
2
From firmware revision 0.11 the maximum value of this interval has been changed from 3000 to 9900
3
From firmware revision 0.11 the maximum value of this interval has been changed from 1000 to 9900
4
The parameter P32 has been inserted from firmware revision 0.10. When used with pressure switch, it’s
necessary to not modify the default value 1.