Technical data
3.2 Ambient conditions and operating conditions
SCHUNK force-torque-sensors are optionally available in versions
with IP60,65or68 protection.
Force-torque-sensors in versions not with IP65 or 68 protection
must be operated in an environment with max. 95% relative air
humidity.
The catalog data sheet contains more information.
Designation Ambient temperature [°C]
FTD / FTN / FTE Nano and Mini Min.
Max.
0
+80
FTD from Gamma and larger Min.
Max.
0
+60
FTD from Gamma and larger
without on-board electronics
Min.
Max.
0
+85
FTN from Gamma and larger Min.
Max.
0
+85
FTE from Gamma and larger Min.
Max.
0
+70
3.3 Measurement error
NOTE
The force-torque-sensors are calibrated at a temperature of 22°C.
If the force-torque-sensors are used at a different ambient
temperature, the accuracy of the measured values changes.
Measurement error from 22°C Nano/Mini from
Gamma and
larger
±5°C 0.1% 0.1%
±15°C 0.5% 0.5%
±25°C 1% 1.5%
±50°C 5% 7%
2303.00 | FT | Assembly and Operating Manual | en | 389582