Technical data
Delta (including IP 60, IP 65 and IP 68)
Calibration F
x
/ F
y
[N]
F
z
[N]
M
x
/ M
y
[Nm]
M
z
[Nm]
F
x
/ F
y
[N]
F
z
[N]
M
x
/ M
y
[Nm]
M
z
[Nm]
SI-165-15 165 495 15 15 1/32 1/16 1/528 1/528
SI-330-30 330 990 30 30 1/16 1/8 5/1333 5/1333
SI-660-60 660 1980 60 60 1/8 1/4 10/1333 10/1333
Ranges of measurement FTD, FTN, FTW, FTE resolution