Technical data
Omega85 (including IP 65 and IP 68)
Calibration F
x
/ F
y
[N]
F
z
[N]
M
x
/ M
y
[Nm]
M
z
[Nm]
F
x
/ F
y
[N]
F
z
[N]
M
x
/ M
y
[Nm]
M
z
[Nm]
SI-475-20 475 950 20 20 1/14 3/28 5/1496 7/2992
SI-950-40 950 1900 40 40 1/7 3/14 5/748 7/1496
SI-1900-80 1900 3800 80 80 2/7 3/7 5/374 7/748
Ranges of measurement FTD, FTN, FTW, FTE resolution