EasyManua.ls Logo

SCHUNK PLZ Plus Series - User Manual

Default Icon
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
Montage- und Betriebsanleitung für 3-Backen-Parallelgreifer
PZN-plus mit Werkzeugschnittstelle HSK/KM/Capto
Operating manual for 3-Finger Parallel Gripper
PZN-plus with tool interface HSK/KM/Capto
3-Backen-Zentrischgreifer PZN-plus
mit Werkzeugschnittstelle
HSK/KM/Capto
3-Finger Centric Gripper PZN-plus
with tool interface
HSK/KM/Capto
SCHUNK GmbH & Co. KG
Spann- und Greiftechnik
Bahnhofstr. 106-134
74348 Lauffen/Neckar
Deutschland
Tel. +49-7133-103-0
Fax +49-7133-103-2189
automation@de.schunk.com
www.schunk.com
AUSTRIA: SCHUNK Intec GmbH
Tel. +43-7229-65770-0 · Fax +43-7229-65770-14
info@at.schunk.com · www.at.schunk.com
BELGIUM, LUXEMBOURG:
SCHUNK Intec N.V. / S. A.
Tel. +32-53-853504 · Fax +32-53-836022
info@be.schunk.com · www.be.schunk.com
CANADA: SCHUNK Intec Corp.
Tel. +1-905-712-2200 · Fax +1-905-712-2210
info@ca.schunk.com · www.ca.schunk.com
CHINA: SCHUNK Representative Office
Tel. +86-21-64433177 · Fax +86-21-64431922
info@cn.schunk.com · www.cn.schunk.com
CZECH REPUBLIC: SCHUNK Intec s.r.o.
Tel. +420-545229095 · Fax +420-545220508
info@cz.schunk.com · www.cz.schunk.com
DENMARK: SCHUNK Intec A/S
Tel. +45-43601339 · Fax +45-43601492
info@dk.schunk.com · www.dk.schunk.com
FRANCE: SCHUNK Intec SARL
Tel. +33-1-64663824 · Fax +33-1-64663823
info@fr.schunk.com · www.fr.schunk.com
GREAT BRITAIN: SCHUNK Intec Ltd.
Tel. +44-1908-611127 · Fax +44-1908-615525
info@gb.schunk.com · www.gb.schunk.com
RUSSIA: OOO SCHUNK Intec
Tel. +7-812-326 78 35 · Fax +7-812-326 78 38
info@ru.schunk.com · www.ru.schunk.com
SLOVAKIA: SCHUNK Intec s.r.o.
Tel. +421-37-3260610 · Fax +421-37-6421906
info@sk.schunk.com · www.sk.schunk.com
SOUTH KOREA: SCHUNK Intec Korea Ltd.
Tel. +82-31-7376141 · Fax +82-31-7376142
info@kr.schunk.com · www.kr.schunk.com
SPAIN: SCHUNK Intec S.L.
Tel. +34-937 556 020 · Fax +34-937 908 692
info@es.schunk.com · www.es.schunk.com
SWEDEN: SCHUNK Intec AB
Tel. +46-8-554-42100 · Fax +46-8-554-42101
info@se.schunk.com · www.se.schunk.com
SWITZERLAND, LIECHTENSTEIN:
SCHUNK Intec AG
Tel. +41-523543131 · Fax +41-523543130
info@ch.schunk.com · www.ch.schunk.com
TURKEY: SCHUNK Intec
Tel. +90-2163662111 · Fax +90-2163662277
info@tr.schunk.com · www.tr.schunk.com
USA: SCHUNK Intec Inc.
Tel. +1-919-572-2705 · Fax +1-919-572-2818
info@us.schunk.com · www.us.schunk.com
HUNGARY: SCHUNK Intec Kft.
Tel. +36-46-50900-7 · Fax +36-46-50900-6
info@hu.schunk.com · www.hu.schunk.com
INDIA: SCHUNK India Branch Office
Tel. +91-80-40538999 · Fax +91-80-41277363
info@in.schunk.com · www.in.schunk.com
ITALY: SCHUNK Intec S.r.l.
Tel. +39-031-4951311 · Fax +39-031-4951301
info@it.schunk.com · www.it.schunk.com
JAPAN: SCHUNK Intec K.K.
Tel. +81-33-7743731 · Fax +81-33-7766500
s-takano@tbk-hand.co.jp · www.tbk-hand.co.jp
MEXICO, VENEZUELA:
SCHUNK Intec S.A. de C.V.
Tel. +52-442-223-6525 · Fax +52-442-223-7665
info@mx.schunk.com · www.mx.schunk.com
NETHERLANDS: SCHUNK Intec B.V.
Tel. +31-73-6441779 · Fax +31-73-6448025
info@nl.schunk.com · www.nl.schunk.com
POLAND: SCHUNK Intec Sp.zo.o.
Tel. +48-22-7262500 · Fax +48-22-7262525
info@pl.schunk.com · www.pl.schunk.com
PORTUGAL: Sales Representative
Tel. +34-937-556 020 · Fax +34-937-908 692
info@pt.schunk.com · www.pt.schunk.com
Reg. No. DE-003496 QM
Reg. No. DE-003496 QM
Druck-Nr.: 03 / PZN-plus-HSK / de-en / 04.03.10 K
Sehr geehrter Kunde,
wir gratulieren zu Ihrer Entscheidung für SCHUNK. Damit
haben Sie sich für höchste Präzision, hervorragende
Qualität und besten Service entschieden.
Sie erhöhen die Prozesssicherheit in Ihrer Fertigung
und erzielen beste Bearbeitungsergebnisse für die
Zufriedenheit Ihrer Kunden.
SCHUNK-Produkte werden Sie begeistern.
Unsere ausführlichen Montage- und Betriebshinweise
unterstützen Sie dabei.
Sie haben Fragen? Wir sind auch nach Ihrem Kauf jeder-
zeit für Sie da. Sie erreichen uns unter den unten aufge-
führten Kontaktadressen.
Mit freundlichen Grüßen
Ihre SCHUNK GmbH & Co. KG
Spann- und Greiftechnik
Dear Customer,
Congratulations on choosing a SCHUNK product. By
choosing SCHUNK, you have opted for the highest preci-
sion, top quality and best service.
You are going to increase the process reliability of
your production and achieve best machining results
to the customer‘s complete satisfaction.
SCHUNK products are inspiring.
Our detailed assembly and operation manual will
support you.
Do you have further questions? You may contact us at
any time – even after purchase. You can reach us directly
at the below mentioned addresses.
Kindest Regards,
Your SCHUNK GmbH & Co. KG
Precision Workholding Systems

Questions and Answers

  • B
    brandy48Aug 16, 2025
    What to do if my SCHUNK PLZ Plus is not moving?
    • H
      hparkerAug 17, 2025
      If your SCHUNK Industrial Equipment is not moving, there are several potential causes: * The base jaws may be jammed in the housing due to an uneven mounting surface. Check the evenness of the mounting surface. * The pressure may have dropped below the minimum required level. Check the air supply. * The compressed air lines may be switched. Check the compressed air lines. * The proximity switch may be defective or set incorrectly. Readjust or change the sensor. * Unused air connections may be open. Close any unused air connections. * The flow control valve may be closed. Open the flow control valve. * A component part may be defective. Replace the component or send it to SCHUNK for repair.
  • S
    Shawn SmithAug 19, 2025
    Why is the gripping force of my SCHUNK PLZ Plus dropping?
    • J
      Joe FoleyAug 19, 2025
      A drop in the gripping force of your SCHUNK Industrial Equipment can occur due to several reasons: * Compressed air may be escaping. Check the seals and replace them if necessary after disassembling the product. * There may be too much grease in the mechanical movement space. Clean and lubricate the product. * The pressure may have dropped below the minimum. Check the air supply. * A component part may be defective. Replace the component or send it to SCHUNK for repair.
  • J
    Julia GillespieAug 22, 2025
    What to do if SCHUNK PLZ Plus is not executing the complete stroke?
    • B
      bankshowardAug 22, 2025
      If your SCHUNK Industrial Equipment isn't completing its full stroke, consider these possibilities: * Dirt deposits may be present between the cover and piston. Clean and re-lubricate if needed. * Dirt deposits may have accumulated between the basic jaws and guidance. Disassemble and clean the product. * The pressure may have dropped below the minimum. Check the air supply. * The mounting surface may not be sufficiently flat. Check the evenness of the mounting surface. * A component part may be defective. Replace the component or send it to SCHUNK for repair.
  • P
    Phillip ReynoldsAug 25, 2025
    Why does my SCHUNK PLZ Plus open or close abruptly?
    • J
      Jasmine WrightAug 26, 2025
      Abrupt movements in your SCHUNK Industrial Equipment may be due to: * Insufficient grease in the mechanical guiding areas. Clean and lubricate the product. * Blocked compressed air lines. Check the compressed air lines for damage. * An uneven mounting surface. Check the evenness of the mounting surface. * A missing or incorrectly adjusted one-way flow control valve. Install and adjust the one-way flow control valve. * An excessive load. Check the permissible weight and length of the gripper fingers.
  • R
    Robert WilliamsAug 30, 2025
    How to troubleshoot a SCHUNK PLZ Plus Industrial Equipment gripper that does not move?
    • S
      Sean HillAug 30, 2025
      If your SCHUNK Industrial Equipment gripper isn't moving, start by checking the air supply. Specifically, ensure that the pressure hasn't dropped below the minimum level, the air lines are correctly connected, the proximity switches are functioning and properly set, any unnecessary air connections are sealed, there's sufficient evenness of the attachment face, and the cylinder piston isn't fractured due to overload.
  • R
    Richard DavisSep 2, 2025
    What to do if SCHUNK Industrial Equipment gripper does not complete the stroke?
    • E
      Elizabeth HobbsSep 2, 2025
      To address a SCHUNK Industrial Equipment gripper that isn't completing its stroke, ensure that the gripper is clean, removing any dirt from between the cover plate and the chuck piston, and between the base jaw and the guide. Also, verify that the pressure hasn't dropped below the minimum level and that the cylinder piston magnet is properly in place. Finally, ensure there's sufficient evenness of the attachment face.
  • C
    chambersnicholasSep 4, 2025
    Why is the gripping force reduced on my SCHUNK PLZ Plus Industrial Equipment?
    • K
      Karen PerkinsSep 4, 2025
      If you're experiencing reduced gripping force with your SCHUNK Industrial Equipment, begin by checking the seals. Additionally, clean and re-lubricate the gripper. Finally, check the air supply to ensure it's adequate.
  • A
    Alexa ParksSep 7, 2025
    What causes a SCHUNK Industrial Equipment gripper to open or close erratically?
    • C
      connie80Sep 7, 2025
      If your SCHUNK Industrial Equipment gripper opens or closes erratically, try cleaning and re-lubricating it. Also, ensure there is sufficient evenness of the attachment face.
  • E
    Emily GriffinSep 10, 2025
    What to do if SCHUNK PLZ Plus module does not move?
    • A
      Ashley AlvaradoSep 12, 2025
      If your SCHUNK Industrial Equipment module isn't moving, there are several potential solutions: * Ensure the bolting surface is level. * Loosen the gripper's mounting screws and reactuate the gripper. * Check the air supply and compressed air lines. * Repair the proximity switch. * Close any unused air connections. * Open the choke valve. If these steps don't resolve the issue, and the module was used within specified parameters, consider replacing the component or sending it to SCHUNK for repair. You may also want to check the application using the calculation program for gripping modules (SSG).
  • J
    Joseph MillerSep 12, 2025
    Why SCHUNK Industrial Equipment module does not travel through the entire stroke?
    • O
      Omar MeyerSep 12, 2025
      If your SCHUNK Industrial Equipment module isn't traveling through its entire stroke, it could be due to a few reasons: * Dirt deposits between the cover and the piston: Remove the cover, clean the module, and relubricate it. * Dirt deposits between the base jaws and the guide: Disassemble and clean the module. * Pressure dropping below minimum: Check the air supply to ensure adequate pressure.

SCHUNK PLZ Plus Series Specifications

General IconGeneral
Opening Time0.1 - 0.3 s
Operating Temperature5 - 60 °C
Gripping Time0.1 - 0.3 s
Repeat Accuracy±0.02 mm
Ambient Temperature5 - 60 °C

Related product manuals