Condition/Problem Things to Check Solution
No display/partial display/
unit will not turn on
Check electrical (wall)
outlet
0DNHVXUHXQLWLVSOXJJHGLQWRDIXQFWLRQLQJZDOORXWOHW
Check connection at front
of unit
&RQQHFWLRQVKRXOGEHVHFXUHDQGXQGDPDJHG5HSODFH
DGDSWHURUFRQQHFWLRQDWXQLWLIHLWKHUDUHGDPDJHG
Check data cable integrity $OOZLUHVLQFDEOHVKRXOGEHLQWDFW,IDQ\DUHYLVLEO\FULPSHGRU
FXWUHSODFHFDEOH
Check data cable
connections/orientation
%HVXUHFDEOHLVFRQQHFWHGVHFXUHO\DQGRULHQWHGSURSHUO\
6PDOOODWFKRQFRQQHFWRUVKRXOGOLQHXSDQGVQDSLQWRSODFH
Check console display for
damage
Check for visual sign that console display is cracked or other
ZLVHGDPDJHG5HSODFH&RQVROHLIGDPDJHG
Console Display ,I&RQVROHRQO\KDVSDUWLDOGLVSOD\DQGDOOFRQQHFWLRQVDUH¿QH
UHSODFHWKH&RQVROH
If the above steps do not resolve the problem, contact Cus
WRPHU&DUHIRUIXUWKHUDVVLVWDQFH
Unit operates but Contact
HR not displayed
HR cable connection at
Console
%HVXUHFDEOHLVFRQQHFWHGVHFXUHO\WR&RQVROH
HR cable box connection Be sure cables from handlebars and cable to Console are
VHFXUHDQGXQGDPDJHG
Sensor grip %HVXUHKDQGVDUHFHQWHUHGRQ+5VHQVRUV+DQGVPXVWEH
NHSWVWLOOZLWKUHODWLYHO\HTXDOSUHVVXUHDSSOLHGWRHDFKVLGH
Dry or calloused hands 6HQVRUVPD\KDYHGLI¿FXOW\ZLWKGULHGRXWRUFDOORXVHGKDQGV
A conductive electrode cream (heart rate cream) can help
PDNHEHWWHUFRQGXFW7KHVHDUHDYDLODEOHRQWKHZHERUDW
PHGLFDORUVRPHODUJHU¿WQHVVVWRUHV
Static Handlebar If tests reveal no other issues, Static Handlebar should be
UHSODFHG
Unit operates but
Telemetric HR not
displayed
Chest Strap (optional) 6WUDSVKRXOGEH³32/$5´FRPSDWLEOHDQGXQFRGHG0DNH
VXUHVWUDSLVGLUHFWO\DJDLQVWVNLQDQGFRQWDFWDUHDLVZHW
Chest Strap Batteries ,IVWUDSKDVUHSODFHDEOHEDWWHULHVLQVWDOOQHZEDWWHULHV
&KHFN8VHU3UR¿OH 6HOHFWWKH(GLW8VHU3UR¿OHRSWLRQIRUWKH8VHU3UR¿OH*RWR
the WIRELESS HR setting and make sure that the current
YDOXHLVVHWWR21
Interference Try moving unit away from sources of interference (TV, Micro
ZDYHHWF
Replace Chest Strap If interference is eliminated and HR does not function, replace
VWUDS
Replace Console ,I+5VWLOOGRHVQRWIXQFWLRQUHSODFH&RQVROH
Unit operates but
Telemetric HR displayed
incorrectly
Interference Make sure that the HR receiver is not blocked by a personal
HOHFWURQLFGHYLFHLQWKHOHIWVLGHRIWKHPHGLDWUD\
Console displays “E2”
error code
Check data cable integrity $OOZLUHVLQFDEOHVKRXOGEHLQWDFW,IDQ\DUHFXWRUFULPSHG
UHSODFHFDEOH
Check data cable
connections/orientation
%HVXUHFDEOHLVFRQQHFWHGVHFXUHO\DQGRULHQWHGSURSHUO\
6PDOOODWFKRQFRQQHFWRUVKRXOGOLQHXSDQGVQDSLQWRSODFH
Console Electronics ,IWHVWVUHYHDOQRRWKHULVVXHVFRQWDFW&XVWRPHU&DUH
TROUBLESHOOTING