SYMPTOM POSSIBLE CAUSE SUGGESTED CORRECTION
Unit will not run Blown fuse or breaker Replace fuse & check for
cause of blown fuse, reset
breaker.
Compressor cycles
intermittently
Low voltage Check voltage at the supply to
the building.
Check circuit for overloading.
Dirty condenser Clean the condenser
Air circulation blocked around
unit
Allow sufficient air around unit
Non condensable gas in
system
Evacuate and recharge with
nameplate charge
Cubes too small Cube size control set too
warm
Check and adjust for proper
operation
Partially restricted cap tube Blow charge, evacuate with
new drier, weigh in nameplate
charge
Moisture in system Same as above
Overcharged Same as above
Undercharged Same as above, look for a
leak.
Cloudy cubes Spray nozzles plugged Clean
Needs cleaning Clean with Scotsman Ice
Machine Cleaner
Irregular size cubes, some
cloudy
Some jets plugged Clean jets
Shortage of water Check water supply
Cubes too large Cube size control set
improperly
Check and adjust for proper
operation
Decreased ice capacity Inefficient compressor Replace