CU50
Service Manual
March 2010
Page 13
Control Settings
Automatic water purge enable / disable
The control is set at the factory to automatically
select the proper amount of water purge. If desired,
that can be disabled, and a typical purge amount
used.
To disable Automatic purge selection:
1. Press and hold the On/Off button until the unit
shuts off. No lights should be on.
2. Press and hold the ON button for 5 seconds,
then release.
3. Wait between 5 and 20 seconds, then repeat
step 1. All lights will ash once.
To return to Automatic purge selection:
1. Press and hold the ON button for 5 seconds,
then release.
2. Wait between 5 and 20 seconds, then repeat
step 1. All lights will ash twice.
Manual Harvest - from the OFF or Standby Mode
(powered but no lights are on)
1. Press and hold the Clean-Reset button for 5
seconds and release.
2. Wait between 5 and 20 seconds, then repeat
step 1. All lights will ash once. The On/Off light will
be on until harvest has timed out.
Reset time to clean indicator light
Press and hold the Clean-Reset button for 3
seconds.