CU50
Service Manual
March 2010
Page 7
Installation Notes
Sealing to oor: In some cases the base of the ice
machine must be sealed to the oor to meet local
code. Food grade silastic sealant such as
Scotsman part number 19-0529-01 is
recommended.
Place the machine in the intended location. Turn
the leg levelers in until the bottom of the unit is as
close to the oor as possible. Be sure the unit is
level and all four levelers are in contact with the
oor.
Place a bead of the sealant between the oor and
the outside edge of the cabinet. The bead must ll
the space between the cabinet bottom edges and
the oor.
Built In Situations: If a nished oor is to be
installed in the area after the ice machine has
been built in, shims the expected thickness of the
oor should be installed under the unit to keep the
machine level with the planned oor level.
Installations on a slab: Use a pump model and
pump the water to the point of drainage. Pump
models will pump 1 story (10 feet) high.
Installations over a crawl space or basement:
Either gravity drain or pump model units may
be used, if there is not enough room behind the
machine for a drain/waste receptacle, the drain will
have to be below the oor.
Note: When installed in a corner, the door swing
may be limited due to handle contact with the wall
or cabinet face.