The 918 EntryCheck™ is a digital keyless entry system
designed for access control applications. The keypad is mounted
on a rugged, stainless steel faceplate and is designed to be
mounted in a standard single-gang electrical box. The indoor
backlit keys have bright, easy-to-read graphics.
Up to 500 entry codes, from 1 to 6 digits in length, can be
programmed. They can activate one or both of the relay
outputs. The programmable “anti-passback” feature prevents
using the same code again before the programmed time
elapses.
All system indicators are long-lasting, solid state LEDs. Two
indicators show the status of the entry system. The left indicator
lights red to indicate power, then turns green when access is
granted. The right indicator lights yellow when the keypad is in
“lockout” condition (from too many incorrect code entries). The
yellow LED flashes when the keypad is in programming mode.
An internal sounder beeps when each key is pressed. An
internal jumper sets the sounder volume high or low
The SENSE input can be used two ways. If programmed for
“door sense” the input is wired to a normally closed door contact
switch to detect when the door is opened or closed. Forced
entry or door ajar situations can then be detected. When using a
door contact switch, the “Auto-relock” feature will prevent
“tailgating” by turning off the Main Relay output immediately
when the door is closed after access has been granted. If the
SENSE input is programmed for “inhibit”, the input can be wired
to a “service” switch or automatic timer that will disable the Main
Relay when required.
The REQUEST-TO-EXIT input may be wired to a pushbutton to
provide codeless activation of Main Relay, Auxiliary Relay,
Output #3 or Output #4 (programmable).
The ALARM SHUNT output activates when access is granted.
This output can be wired to shunt alarm contacts on the access
door/gate to prevent triggering of an alarm when authorized
access occurs.
The 918 EntryCheck™ is powered from a 12/24VDC or AC
source. The EEPROM memory retains all entry codes and
programming, even without power. An internal jumper is
provided to reset the master code. The Main Relay has a 5 Amp
capacity. The Auxiliary Relay has a 2 Amp capacity. Two solid
state outputs, capable of switching 100 mA to common, are
programmable to signal forced entry, door ajar, lockout, alarm
circuit shunting, request-to-exit, and keypad active conditions.
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com P:\ INST INSTRUCTIONS\ACCESS CONTROLS\INST-918 REV D 11-21 Page 1
918 EntryCheck
TM
Security Door Controls
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: service@sdcsecurity.com ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
INSTALLATION INSTRUCTIONS
Features
 Keypad programmable
 500 user codes
 1 to 6 digit user codes
 4 independent outputs
 4 independent timers
 2 Form C relay contacts
 2 solid state open collector outputs
 Program entry codes to activate one or both
relays
 Disable input
 Door sense input
 Request-to-exit/enter input
 Keypad tamper lockout
 Timed anti-passback
 Anti-tailgate
 Two LED status indicators
 Tactile key feel
 Audible code entry verification
 12 or 24V, AC or DC operation
SPECIFICATIONS
Mechanical
Dimensions: 3.00" W x 4.75" H x 1.50" D
(.250”D wall extrusion)
Electrical
Input Voltage: 12/24 Volts DC or AC
Operating Current: 30 mA typical, 150 mA max
Output Ratings
Main Relay: Form “C” 5 Amps @ 28 Volts max
Auxiliary Relay: Form “C” 2 Amp @ 28 Volts max
Type: Solid state outputs (Outputs #3 & #4)
Short-to-common 100 mA @ 24 VDC maximum
Environmental
Temperature: -22°F to 149°F (-30°C to 65°C)
Humidity: 5% to 95% non-condensing
Question and Answer IconNeed help?

Do you have a question about the SDC EntryCheck 918 and is the answer not in the manual?

Overview

The SDC 918 EntryCheck™ is a digital keyless entry system designed for access control applications. It features a rugged, stainless steel faceplate and is designed for mounting in a standard single-gang electrical box. The indoor backlit keys provide bright, easy-to-read graphics.

Function Description:

The 918 EntryCheck™ allows for programming up to 500 entry codes, each ranging from 1 to 6 digits in length. These codes can activate one or both of the system's relay outputs. A programmable "anti-passback" feature prevents the same code from being used again before a programmed time elapses.

The system includes long-lasting, solid-state LED indicators. The left indicator lights red for power and turns green when access is granted. The right indicator lights yellow to indicate a "lockout" condition (triggered by too many incorrect code entries) and flashes yellow when the keypad is in programming mode. An internal sounder provides audible feedback with each key press, and its volume can be adjusted via an internal jumper.

The SENSE input offers dual functionality:

  • Door Sense: When programmed for door sense, this input connects to a normally closed door contact switch. It detects when the door is opened or closed, allowing for detection of forced entry or door ajar conditions. With a door contact switch, the "Auto-relock" feature immediately turns off the Main Relay output when the door closes after access has been granted, preventing "tailgating."
  • Inhibit: When programmed for inhibit, the input can be wired to a "service" switch or automatic timer to disable the Main Relay when required.

The REQUEST-TO-EXIT input can be wired to a pushbutton to provide codeless activation of the Main Relay, Auxiliary Relay, Output #3, or Output #4 (programmable).

An ALARM SHUNT output activates when access is granted. This output can be wired to shunt alarm contacts on the access door/gate, preventing an alarm from triggering during authorized access.

The 918 EntryCheck™ is powered by a 12/24VDC or AC source. Its EEPROM memory ensures that all entry codes and programming are retained even without power. The Main Relay has a 5 Amp capacity, and the Auxiliary Relay has a 2 Amp capacity. Two solid-state outputs, capable of switching 100 mA to common, are programmable to signal various conditions such as forced entry, door ajar, lockout, alarm circuit shunting, request-to-exit, and keypad active.

Important Technical Specifications:

  • Mechanical:
    • Dimensions: 3.00" W x 4.75" H x 1.50" D (.250"D wall extrusion)
  • Electrical:
    • Input Voltage: 12/24 Volts DC or AC
    • Operating Current: 30 mA typical, 150 mA max
  • Output Ratings:
    • Main Relay: Form "C" 5 Amps @ 28 Volts max
    • Auxiliary Relay: Form "C" 2 Amp @ 28 Volts max
    • Solid State Outputs (Outputs #3 & #4): Short-to-common 100 mA @ 24 VDC maximum
  • Environmental:
    • Temperature: -22°F to 149°F (-30°C to 65°C)
    • Humidity: 5% to 95% non-condensing

Usage Features:

  • Keypad Programmable: All settings and codes are programmed directly through the keypad.
  • User Codes: Supports 500 user codes, 1 to 6 digits in length.
  • Outputs and Timers: Features 4 independent outputs and 4 independent timers.
  • Relay Contacts: Includes 2 Form C relay contacts and 2 solid-state open collector outputs.
  • Relay Activation: Entry codes can be programmed to activate one or both relays.
  • Disable Input: Allows for temporary disabling of the keypad.
  • Door Sense Input: Detects door status (open/closed).
  • Request-to-Exit/Enter Input: Provides codeless access.
  • Keypad Tamper Lockout: Locks out the keypad after too many incorrect code attempts.
  • Timed Anti-Passback: Prevents immediate re-use of a code.
  • Anti-Tailgate: Prevents unauthorized entry after an authorized user.
  • LED Status Indicators: Two LEDs provide visual status feedback.
  • Tactile Key Feel: Keys provide a responsive feel.
  • Audible Code Entry Verification: Sounder confirms key presses.
  • Power Options: Operates on 12 or 24V, AC or DC.
  • Toggle Mode: Outputs can be programmed to alternate between OFF and ON with each activation, useful for extended access periods (e.g., normal business hours).
  • Master Code Reset: An internal jumper (JP2) allows for resetting the master code to its default (123456) without clearing other programming.
  • Factory Defaults: The system comes with pre-set default values for all programming options, including a Master Programming Code of 123456, 4-digit entry code length, and 2-second activation times for relays and solid-state outputs.

Maintenance Features:

  • Master Reset: A full master reset procedure (disconnect power, hold * and # keys, apply power, release keys) clears all memory and returns all programmable options to factory default values, erasing all entry codes.
  • Beeper Sound Level: An internal jumper (JP1) allows for adjusting the beeper sound level (high or low).
  • EEPROM Memory: Retains all entry codes and programming even during power loss, minimizing reprogramming needs after outages.
  • Troubleshooting Indicators: Red and yellow LEDs provide visual cues for incorrect entries, programming errors, and lockout conditions, aiding in troubleshooting.

SDC EntryCheck 918 Specifications

General IconGeneral
BrandSDC
ModelEntryCheck 918
CategoryDoor locks
LanguageEnglish

Related product manuals