Beep Sounds During Auxiliary Relay Default: No
Selects whether or not the keypad beeps during Auxiliary Relay
activation.
Press: 4 2 # Sound
#
Sound=1 for Yes, =0 for No
Beep Sounds During Output #3 Default: No
Selects whether or not the keypad beeps during Output #3
activation.
Press: 4 3 # Sound
#
Sound=1 for Yes, =0 for No
Beep Sounds During Output #4 Default: No
Selects whether or not the keypad beeps during Output #4
activation.
Press: 4 4 # Sound
#
Sound=1 for Yes, =0 for No
Beep Sounds During Main Relay Default: No
Selects whether or not the keypad beeps during Main Relay
activation.
Press: 4 1 # Sound
#
Sound=1 for Yes, =0 for No
Solid-state Output #4 On-time Default: 2 Seconds
Sets the length of time Output #4 activates when triggered.
Press: 2 4 # Seconds
#
Seconds=Output time in seconds (0-60)
Beep Sounds on Keystrokes Default: Yes
Selects whether or not the keypad beeps as each key is pressed.
Press: 4 0 # Sound
#
Sound=1 for Yes, =0 for No
Door Ajar Timer Default: 60 Seconds
Sets the amount of time the door may be held open after an
authorized access. The DOOR AJAR output will activate after
the time expires.
Press: 25 # Seconds
#
Seconds=Held open time in seconds (1-60)
Keypad Lockout Count Default: 3 Tries
Sets the number or incorrect entry code attempts allowed
before the keypad “locks out”.
Press: 5 0 # Attempts
#
Attempts=Number of attempts before lockout (2-7)
Anti-Pass Back Time Default: No Anti-Pass Back
Sets the length of time an entry code will not function after it is
used.
Press: 5 1 # Minutes
#
Minutes=Time in minutes (1-4), 0=No Anti-passback
RESETTING KEYPAD
Master Reset
CAUTION: Performing a master reset will clear the
entire memory of the 918 and return all programmable
options to the factory default values. ALL ENTRY
CODES WILL BE ERASED.
STEP 1 Disconnect power from the keypad.
STEP 2 Press and hold down the * and # keys.
STEP 3 Apply power to the keypad, continue holding the keys
down until the red indicator starts flashing
STEP 4 Release the keys. The red and yellow indicators will
remain lit until the process is complete, then the
yellow indicator will go out.
Resetting the Master Code
STEP 1 Remove the 918 from the wall..
STEP 2 Locate jumper at JP2. This jumper is used to reset
the master code.
STEP 3 With power applied to the keypad, remove the jumper
at JP2. The keypad will begin to beep, signaling that
the code has been reset.
STEP 4 Replace jumper on JP2
THE MASTER PROGRAMMING CODE IS NOW 123456.
Beeper Sound Level
The Keypad’s beeper can be set to high or low level.
Remove jumper JP1 to reduce beeper sound level.
Selects mode for Keypad LED Backlight Default: 30 Seconds
Selects whether or not the keypad back light stays OFF, lights for
30 seconds when activated or stays ON.
Press: 52 # Output
#
0 = Light always OFF
1 = 30 sec light when activated (default)
2 = Light always ON