4.2. Operation
When the engine begins to heat up, gradually bring the choke tab to the open position.
When the running speed of the generating set has stabilised:
n Check that the circuit breaker(s) (no. 22, Fig. A) is (are) connected.
o Connect the plug(s) to the generating set socket(s).
4.3. Switching off
When the generating set is turned off, the engine continues to give off heat.
Appropriate ventilation should be provided after the generating set is turned off.
To stop the generating set urgently, place the engine switch on "OFF" or "О".
Warning
n Take the plugs out of the sockets and allow the engine to run without any charge for 1 to 2 minutes.
o Place the engine switch on "OFF" or "О" and the set will stop.
p Close the fuel tap.
5. Safety features (if fitted, see specifications table)
5.1. Oil cut-out
This mechanism is designed to prevent any damage to the motor resulting from lack of oil in the motor sump. It automatically cuts out
the motor. If the motor stops and will not restart, check the motor oil level before looking for any other cause of the problem.
5.2. Circuit breaker
The electrical circuit of the set is protected by several magnetothermal, differential or thermal cut-out switches. Any overload and/or
short circuits cause the supply of electrical energy to be cut.
6. Maintenance schedule
6.1. Reminder of use
The maintenance interval frequency and the operations to be carried out are outlined in the maintenance programme.
However, it should be added that it is the environment in which the generating set is operating which determines this programme.
Accordingly, if the set is used in extreme conditions, shorter intervals between maintenance procedures should be adopted.
These maintenance schedules apply only to generating sets running on fuel and oil, that conform to the specifications given in this
booklet.
6.2. Maintenance table
carry out these maintenance
procedures at whichever of the two
intervals is reached first
part
Each time it
is used
After the first
20 hours of
use
Every 3
months or 50
hours
Every 6
months or
100 hours
Every 12
months or
300 hours
Engine oil Check the level
•
Change
•
•
Air filter Check
•
Clean
(1)
Sediment bowl Clean
•
Spark plugs Check / clean
•
Spark arrester Clean
•
Valve clearance Check / adjust
(*)
Strainer and petrol
tank
Clean
(*)
Cleaning the generating set
•
Fuel line Check (replace if
necessary)
Every 2 years (*)
Note: * This operation should be carried out by one of our agents
(1): Perform air filter maintenance more frequently for operation in dusty locations.