HotFind-D Infrared Camera Operation Manual
38
9 Technical Specification of SDS HotFind-D
Environmental Requirements of SDS HotFind-D
1
Operating
temperature
-15℃~50℃
2 Operating humidity ≤90%
3 Storage temperature
-40℃~70℃
Technical Indexes of SDS HotFind-D
4 Type of Detector
Focal Plane Array (FPA), uncooled
microbolometer
5 Spectral range
8~14um
6 Weight
≤0.7Kg (including battery)
7 NETD
0.1℃
8
Temperature
range
-20 ~+250 ℃(HotFind-D)
-20 ~+600 ℃(HotFind-DX)
-20 ~+1000 ℃(HotFind-DXS)
-20 ~+1500 ℃(HotFind-DXT)
9
Temperature
accuracy
±2℃/±2% of reading
10
Battery operating
time
App. 2 hours
11 FOV 20°×15°/10mm
12 Spatial resolution 2.2mrad
13 Pixel 160×120
14
Image display and
temperature
measurement
Full-screen pseudocolor and full-screen
temperature measurement
15 Structure Integrated design and one-hand operation
16
Frame frequency/
output pattern
composite video
17 Packing High-strength plastics portable case
Temperature Measurement of SDS HotFind-D
18 Operation windows-style English menu, operated with keys
19 Adjustment automatic/ manual gain