IDS701 User Manual
Page 21 of 25
5.5 Print the accumulated output format
NO. 004 (NO.)
Date: XX.XX.XX (year. month. date)
Time: XX.XX.XX (hour. minute. Second)
Total: 003 (accumulate times,example for 3 times is 003)
Total.W: 2.88kg (accumulate weight)
6. Maintenance
6.1 Regular Error and maintain method
1. the loaded weight
excess overload
range of max. capacity
2. wrong connection
with load cell or no
connection with it.
3. load cell
unworkable
1.decrease loaded weight
2. check load cell
connection
3. checking load cell :
check input and output
resistance to judge it is
good or not.
1. calibration is no
good
2、 cell single line is
connect a wrong line.
3、the cell is bad.
1. check scale is resisted
or not, foot is kept level
or not.
2. check load cell
connection.
3. checking load cell :
check input and output
resistance to judge it is
good or not.