EasyManua.ls Logo

SeaDoo XP DI - Output Signal Faults

SeaDoo XP DI
801 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 06 ENGINE MANAGEMENT (RFI)
Subsection 02 (DIAGNOSTIC PROCEDURES )
Output Signal Faults
FAULT CODE
FAULT DETECTION
MPEM programmer B.U.D.S.
TYPE OF FAULT
04 E1 1C
P 0262
• Short circuit to battery
04 E1 1D P 0261
• Short circuit to ground
Injector 1
04 E1 1E P 1200
• Interruption or open circuit
04 E2 1C
P 0265
• Short circuit to battery
04 E2 1D P 0264
• Short circuit to ground
Injector 2
04 E2 1E P 1201
• Interruption or open circuit
Fuel pump
04 EB 1C
P 0230
• Short circuit to battery
Not applicable
04 FC
N.A.
• Not applicable
04 DB 1C
P 0478
• Short circuit to battery
04 DB 1D P 0477
• Short circuit to ground
RAVE vacuum solenoid
04 DB 1E P 0479
• Interruption or open circuit
306 smr2004-Complete Line Up
www.SeaDooManuals.net