Barracuda 18XL Product Manual, Rev. A 91
29 00 Power-on or pin 40 bus reset occurred N
29 01 Power-on occurred Y
29 02 SCSI bus reset occurred Y
29 03 Bus Device Reset function occurred Y
29 04 Device internal reset occurred Y
29 05 Transceiver mode changed to single-ended Y
29 06 Transceiver mode changed to LVD Y
2A 00 Parameters changed by another initiator N
2A 01 Mode select parameters changed by another initiator Y
2A 02 Log parameters changed Y
2A 03 Reservation Preempted N
2C 00 Command sequence error Y
2F 00 Tagged commands cleared by another initiator Y
31 00 Format command failed Y
32 00 Defect locations not available Y
37 00 Rounded parameter error Y
39 00 Saved parameters not supported N
3D 00 Identify message with invalid bits N
3E 03 Logical unit failed self-test Y
3F 00 Target operation command changed Y
3F 01 Microcode changed N
3F 02 SCSI-1/SCSI-2 change N
3F 0F Echo buffer overwritten Y
3F 90 Invalid CAP block Y
40 00 Target operating conditions have changed N
40 01 DRAM parity error detected Y
40 93 Error in write to flash N
42 00 Power on or self test error Y
43 00 Message reject error Y
44 00 Internal controller error Y
45 00 Selection or reselection error Y
47 00 Bus parity error Y
48 00 Initiator detected error Y
49 00 Initiator received invalid message from drive Y
4E 00 Drive attempted overlapped commands Y
5B 00 Log exception—factory option Y
5B 01 Threshold condition met—factory option Y
5B 02 Log counter reached maximum value—factory option Y
5B 03 Log list codes all used—factory option N
5C 00 RPL status change, drive lost synchronization N
5D FF False failure prediction threshold exceeded Y
65 00 Voltage Fault Y
80 00 General firmware error qualifier Y
81 00 Reassign power fail recovery failed Y
Bytes
Description Supported12 13