OPERATION
MANUAL
Product: Document #: Rev: Page:
SEAKEEPER 6 90403 1 10 of 10
Section 2: SYSTEM OPERATION
The circuit breakers should be left on as long as possible
while the Seakeeper is spinning to remove heat from the
Seakeeper. During normal operation, the Seakeeper
should be stopped when pulling into port and stabilization
is no longer required. This maximizes long term life as it
allows the Seakeeper to start the coast down cycle before
cooling is shutoff. Once the vessel is secured in the slip
and the crew has shut down the generator and engines,
the AC and DC breakers that control the Seakeeper should
be switched to the OFF position. The Seakeeper will
continue to spool down to zero rpm. No cooling is
required during this time. Note Seakeeper will take
approximately 4+ hours to coast down to zero rpm from
full speed. The Display will indicate 0 RPM when the
flywheel has stopped.
Note: The seawater pump may run for up to 5 minutes after the
Seakeeper is switched off and is coasting (with AC power applied).
!