The output of the generator is reduced when the temperature, the humidity and the altitude are higher than standard atmospheric
conditions.
Additionally,theloadmustbereducedwhenusinginaconnedareas,asgeneratorcoolingisaffected.
7.2. START ENGINE (ELECTRIC START) FIG.2
7.2.1. Turn ESC switch to OFF.
NOTE: The choke is not required to start a warm engine.
7.2.2. Turn the switch to “CHOKE” position if engine is cold.
7.2.3. Ignition circuit is switched on.
7.2.4. Fuel is switched on.
7.2.5. Presstheredelectricstartswitchasshownintheg.2.
7.3. RECOIL START
7.3.1. Follow choke instructions as above.
7.3.2. Pull slowly on the recoil starter until it is engaged, then pull it briskly.
NOTE:Graspthecarryinghandlermlytopreventthegeneratorfromfallingoverwhenpullingtherecoilstarter.
7.4. After the engine starts, warm up the engine until the engine does not stop when the choke knob is returned to the “ON” position.
NOTE: When starting the engine, with the ESC “ON”, ensure there is no load on the generator.
7.5. STOP ENGINE
NOTE: Turn off any electric devices.
7.5.1. Turn the ESC to “OFF”.
7.5.2. Disconnect any electric devices.
7.5.3. Turn the switch knob to “OFF”. Ignition circuit is switched off. Fuel is switched off.
7.6. ALTERNATING CURRENT (AC) CONNECTION
7.6.1. Ensure all electric devices including the lines and plug connections are in good condition before connection to the generator.
7.6.2. Make sure the total load is within generator rated output.
7.6.3. Ensure the receptacle load current is within receptacle rated current.
NOTE: Make sure to ground (Earth) the generator. When the electric device is earthed, the generator must be earthed.
7.6.4. Start the engine.
7.6.5. Turn the ESC to “ON”.
7.6.6. Plug device into AC socket.
7.6.7. Make sure the AC pilot light is on.
7.6.8. Turn on any electric devices.
NOTE: The ESC must be turned to “OFF” to increase engine speed to rated rpm. If the generator is connected to multiple loads or
electricityconsumers,pleaseremembertorstconnecttheonewiththehigheststartingcurrentandconnecttheonewiththelowest
starting current last.
7.7. BATTERY CHARGING FIG.3
7.7.1. Generator DC rated voltage is 12V.
7.7.2. Connectthenegativepoleofthebatteryrst.
7.7.3. The battery will then be charged.