7.8. APPLICATION RANGE
7.8.1. Ensure the total load on the generator is within the rated output of the generator. Otherwise damage could occur.
7.8.2. Application wattage indicates when each device is used by itself.
7.8.3. The simultaneous usage of AC and DC power is possible but total wattage should not exceed the rated output.
Generator rated output = 3200W
Frequency Power factor
AC 1.0 ≤3500W
DC - 100W(12V/8.3A)
7.8.4. The overload indicator light comes on when total wattage exceeds the application range.
8 DO NOT overload. The total load of a single appliance or the total load of all electrical appliances must not exceed the supply range of
the generator. Overloading will damage the generator.
7.8.5. When supplying precision equipment, electronic controllers, PCs, Electronic computers, microcomputer based equipment or battery
chargers,keepthegeneratorasufcientdistanceawaytopreventelectricalinterferencefromtheengine.Alsoensurethatelectrical
noise form the engine does not interfere with any other electrical devices located near the generator.
7.8.6. Ifthegeneratoristosupplymedicalequipment,adviceshouldrstbeobtainedfromthemanufacturer,amedicalprofessionalor
hospital.
7.8.7. Some electrical appliances or general-purpose electric motors have High starting currents, and cannot therefore be used, even if they
lie within the supply ranges given in the above table. Consult the equipment manufacturer for further advice.
8. MAINTENANCE
WARNING! Stop the engine before servicing. Put the engine on a level surface and remove the spark plug cap to prevent the engine
from starting.
8.1. The engine must be properly maintained to ensure its operation be safe, economical and trouble-free, as well as eco-friendly.
8.2. In order to keep your petrol engine in good working condition, it must be periodically serviced. The following maintenance schedule
and routine inspection procedures must be carefully followed:
Original Language Version
© Jack Sealey Limited
1 0.8-0.95 0.4 - 0.75
(efciency0.85)
≤3500W ≤2800W ≤1190W
Items Each time 1st month or
1st 20hrs of
operation
Thereafter every
3 mths or 50hrs
of operation
Every year or
every 100hrs of
operation
Engine oil Checkrell Yes Yes
Replace Yes Yes
Reduction gear oil
(if equipped)
Oil level check Yes
Replace Yes Yes
Airlterelement Check Yes Yes
Clean Yes
Replace Yes
Deposit cup (if
equipped)
Clean Yes
Spark plug Check adjust Yes
Replace Every year or 250 hours of operation
Spark arrestor Clean Yes
Idling (if
equipped)*
Check adjust Yes
Valve clearance* Check adjust Yes
Fuel tank & fuel
lter*
Clean Yes
Fuel line Check Every 2 years (change if necessary)
Cylinder head,
piston
Clean off carbon* <225cc, every 125hrs
≥225cc,every250hrs
* These items
should be
maintained and
repaired by
manufacturer
unless owner
has appropriate
knowledge, skills
and training to
perform them.
G3500I Issue 1 10/02/23