EasyManua.ls Logo

SealMaster SP 300 - Operating Water Fog Nozzle; Squeegee Application of Sealer

SealMaster SP 300
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
SQUEEGEE SP300
OPERATING WATER FOG NOZZLE:
12. During very hot weather, better adhesion of sealer to
blacktop can be obtained by the use of the water fog. Water
spray will cool down the asphalt and help mix any dust missed
during the cleaning operation. The water tank fill is located under
the left sidestep. Always use clean water to avoid plugging water
lines.
13. Engage water toggle switch #7 labeled water pump, to the
UP position.
SQUEEGEE APPLICATION OF SEALER:
14. Lower the rear assembly valve lever #H-14 by moving,
labeled Rear Assembly, to DOWN position.
15. Place your feet on the peddles:
Push down with the toe part of your foot to OPEN valves.
Press with the heel to CLOSE valves.
Keep sealer in a roll of 1 to 3 inches for full 90” application. If you
are sealing on a hill going horizontal, use only the flow control
valve toward the top of the hill. This will prevent material from
running out of the forward squeegee box.
16. The rear assembly valve lever #H-15 can be angled LEFT or
RIGHT by pushing forward or pulling back. Angling the squeegee
allows the operator to leave a “wet” edge on extremely long
pulls.

Table of Contents