253.872.0284 Page 4 seametrics.com
AG2000 INSTRUCTIONSINSTALLATION
Installing the Gaskets.
1. Select a suitable full-face gasket.
• Only use at compressible gaskets (either pliable
or hard ber will work).
• Use a material compatible with the uid you will
be using.
• Thickness should be 1/8” - 1/4” (3 - 6 mm),
depending on the atness of the pipe ange
surface.
• Inner diameter must be larger than opening in
ow meter.
2. Be sure all mating surfaces are smooth and free of
debris.
3. Install gaskets on each end of meter as shown in
diagrams at right.
Tightening Flange Bolts.
NOTE: Mating pipe anges must be ANSI 150# full face (FF)
and/or raised face (RF).
1. Tighten ange bolts in an alternating pattern.
a. Tighten left ange bolt-1 to 20% recommended
torque.
b. Tighten right ange bolt-1 to 20% of
recommended torque.
c. Repeat steps a and b for each bolt in an
alternating order, such as shown at right,
tightening to 40%, then 60%, then 80%, and
then 100%.
2. Test for leaks.
3. If needed, tighten further in 10% increments until
leaking stops. DO NOT over-tighten. Over-tightening
can cause serious damage to the ow meter.
4. Recheck after 24 hours, adjusting if needed.
Santoprene Liner
Pipe Size ft-lb Nm
3” 25 34
4” 20 27
6” 42 57
8” 65 88
10” 73 99
12” 97 132
SUGGESTED FLANGE BOLT TORQUE
GASKETS
Gaskets are required at all
junctions.
CAUTION!
Improper tightening sequence
can cause serious damage to
the ow meter.
• Do not tighten one side at a time.
• Do not tighten each bolt completely
at one time.
1
2
3
4
5
6
7
8
Suggested tightening sequence.
Gaskets
Gaskets
Grounding
Rings
Installation without grounding rings
Installation with grounding rings