Searey LSA – Pilot’s Operating Handbook Version 5.0, Revision 8
26
Choke (none if engine warm)
Throttle Closed to 1/4” open
Ignition Switch to Both Position, then twist to
Start (No more than 10 seconds)*
Oil Pressure normal range (within 10 seconds)
Radio & Electrical Equipment as Required
*CAUTION: Per Rotax engine operating instructions, engine should not be cranked for
starting for more than 10 seconds at a time. If engine does not start, check choke (fuel
enrichener circuit to be on at cold start) and give a 2 minute cool-down period between
cranks. Abusing this procedure can result in melted wire and fire hazard
4.3 TAXIING
Seat Belts & Shoulder Harness On
Trim – Full Up for Takeoff
Fuel – Double Check (Minimum 4 gallons)
Electric Fuel Pump(s)- 914UL has 2 electric fuel pumps
L & R Ignition - RPM drop - not more than 115
Engine Instruments (Temps) & Ammeter in Green
Minimum Oil Temperature 120 F
Strobe and Nav Lights (As Needed)
4.3.1 TAXIING – ADDITION FOR WATER OPERATION
If Taxiing in water, the following checks must be completed in addition to the
checks listed in paragraph 4.3.