SPR0136037 Rev. 1.5
15
Motor
overheats
The discharge pressure is too
high
Check the setting of pressure relief valve
The discharge line is incorrectly
sized
Check the length and diameter of discharge
line
The power supply does not cor
respond the electronic specificat
ions
Make sure that the power supply
corresponds to motor
Work
with noise
Wrong electrical connections
Check and rectify connections
Lack of lubricant in the mechan
ism/gearbox
Refill with the correct lubricant
Excessive wear of the mechani
sm/gearbox
Overhaul mechanism/gearbox
The pipeline
vibrates
Pipe diameter too small
Enlarge pipe diameter
Pulsation damper out of operation
or too small
Repair or recalculate damper volume
6. Handling and storage
6.1 Handling
Here below is instructions for handling
- Do not sling, pull, push the pump head nozzles or flanges
- Do not sling, pull, push the adjustment knob
6.2 Storage
Precautions
During shipment and storage, the protection against rain, sand, dust, dirty and direct sunlight are
required.
Should the pump be stored for a long time, please store it in a dry and ventilated place.
Important Instruction for MSA/MSV Series
1) Please make sure that this instruction is attached to the pump
2) Make sure that the voltage and frequency is matched. Power supply: 380V/50Hz (or
220V/50Hz, refer to label for details), the motor temperature should be lower than 80 under
normal operation; It is strictly forbidden to operate without liquid for long time (not exceeding 3
minutes)
3) The pump is unable to work at the pressure exceeding its rated pressure (max working
pressure), and its rated pressure value is marked on the label, expressed by bar
(1bar=1kg/cc=10mlift). If the pump works overpressure, it might be damaged.
4) When the chemical to be dosed reacts to water, for example concentrated sulfuric acid, the
chamber must be cleaned and dried (some water drop might be left while testing at our factory)
5) When the adjustment knob is positioned below 100% graduation, the voice from internal
mechanism is relatively big, this is normal, in addition, we suggest you not to position below 30%
graduation.
6) Please make sure that the discharge/ suction line is installed correctly, and the suction line
(suction valve) is installed downward vertically; the discharge line (discharge valve) is installed
upward vertically; the discharge valve does not replace the suction valve each other. Loss of any