Frequency signal input “TRIGGER” activated)
nal set, the pump doses a quantity
that can be programmed in ml. It is possible to set a delay time before
) and the interval between subsequent dosings
) as illustrated in the diagram:
time = 0, a system is obtained in
which the programmed quantity is dosed after each
(with any delay that has been set):
It is possible to start the dosing by pressing the + key, which, in
(it is activated when the
input passes from the open to the closed mode) or to
activated when the input passes from the closed to the open mode).
is locked during dosing (its receipt is neither stored
) input cannot be programmed and its
activation stops the dosing, while its further deactivation makes the
system wait again for the
The dosage frequency can be modified while the pump is operating,
keys at the same time to increase the
Display during Setting (MODE key)
The following are shown in sequence:
quantity to dose, delay in d.hh.mm.
Value of the dosing percentage,