EasyManua.ls Logo

Senco FramePro 651 - User Manual

Senco FramePro 651
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
FramePro
®
600
Series
FramePro
®
700XP
Series
Full Round Head
Full Round Head
FramePro
®
721
© 2014 by Senco Brands, Inc.
HVFN020 Revised March 14, 2014
(Replaces 1/30/08)
Senco Brands, Inc.
4270 Ivy Pointe Blvd.
Cincinnati, OH 45245
1-800-543-4596
www.senco.com
Question and Answer IconNeed help?

Do you have a question about the Senco FramePro 651 and is the answer not in the manual?

Summary

Framing Nailer Operating Instructions

Employer Responsibilities

Safe Tool Handling and Operation

Review Safety Instructions Manual

Must read and understand the 'SAFETY INSTRUCTIONS' manual before using the tool.

Proper Tool Pointing and Air Connection

Always point the tool away from yourself and others, and connect air to the tool.

Avoid Using Damaged Tools

Never use a tool that has air leaks or requires repair.

Tool Use and Loading Procedures

SN70 Nail Guide Installation

Install the Nail Guide (GC0631) for nails shorter than 2 1/2 inches.

FramePro Loading Instructions

Insert nails into magazine, use genuine SENCO fasteners, do not load with safety or trigger depressed.

Contact Actuation Trigger Modes

Nails can be driven two ways: 'Trigger Fire' or 'bottom-fire' mode.

Single Sequential Trigger Operation

Nails can only be driven one way: depress safety element, then pull trigger.

Customer Satisfaction and Safety Reminder

Read the CSSR for safety information regarding Dual Action and Restrictive triggers.

SN60 MC Loading Instructions

Position Nail Guide, insert nails, use SENCO fasteners, do not load with safety or trigger depressed.

Tool Activation and Depth Adjustment

SN60 MC Tool Activation Process

Activate tool by positioning nail, depressing tool against surface, and pulling trigger.

Fastener Depth Adjustment Method

Adjust fastener depth by using a wrench or screwdriver, disconnect air supply first.

FramePro XP Depth Adjustment

Adjust FramePro XP depth using the wheel, disconnect air supply first.

Clearing Nail Jams

Disconnect air, release feeder shoe, remove fasteners, slide magazine back.

SN70 Specific Tool Use Procedures

SN70 E-Z Clear Latch Operation

Release E-Z Clear latch to open the door for clearing jams.

Clearing SN70 Jammed Fasteners

Remove jammed fastener, close door and latch, then clear guide body.

SN70 Magazine Loading and Securing

Loosen knob, pull magazine back, slide back into position, tighten knob.

Reconnecting Air Supply and Loading

Connect air supply, replace fasteners, and pull feeder shoe back.

Tool Features and Lockout Mechanism

FramePro Conversion to Non-Toenail

Convert tool for flat surface applications by adding the no-mar pad.

Exhaust Deflector Adjustment

Rotate deflector to change exhaust air direction; disconnect air supply first.

FramePro Lockout Feature

Tool prevents activation with 6 or fewer nails or when magazine is not locked.

Maintenance Procedures

Review Safety Instructions Manual

Read and understand the 'SAFETY INSTRUCTIONS' manual before using the tool.

Screw Tightness and Part Integrity

Keep all screws tight to ensure safe operation and prevent part breakage.

Daily Safety and Trigger Inspection

Inspect safety element and trigger for free movement when tool is disconnected.

Pneumatic Tool Lubrication

Apply Senco pneumatic oil to air inlet twice daily; use only recommended oil.

Daily Cleaning and Wear Inspection

Wipe tool clean daily and inspect for wear; use non-flammable cleaning solutions cautiously.

Troubleshooting Common Issues

SN70 Air Leak and Sluggish Operation

Troubleshoot air leaks near top or sluggish operation by checking supply and tightening screws.

SN70 Air Leak and Poor Return

Address air leaks near bottom or poor return by cleaning tool or tightening screws.

SN60 MC Air Leak and Sluggish Operation

Fix air leaks near top or sluggish operation by tightening screws or installing a repair kit.

SN60 MC Air Leak and Poor Return

Resolve air leaks near bottom or poor return by cleaning the tool or tightening screws.

FramePro Other Problems

For other FramePro problems, contact SENCO for assistance.

SN70 Nail Specifications

SN70 JF and GE Nail Codes

Specifications for SN70 JF and GE nail codes, including length in inches and mm.

SN70 GC, HC, HF, KC Nail Codes

Specifications for SN70 GC, HC, HF, KC nail codes, including length and diameter.

FramePro FRH Series Nail Specifications

FramePro 602;702 XP FRH Nail Codes

Specifications for FramePro 602/702XP FRH nail codes (GL, GD, HD, HL, KD, D).

FramePro 652;752 XP FRH Nail Codes

Specifications for FramePro 652/752XP FRH nail codes, including length and diameter.

FramePro CH Series Nail Specifications

FramePro 601;701 XP CH Nail Codes

Specifications for FramePro 601/701XP CH nail codes (GE, GC, HC, HE, H, KC, C).

FramePro 651;751 XP CH Nail Codes

Specifications for FramePro 651/751XP CH nail codes, including length and diameter.

SN60 MC Staple Specifications

SN60 MC KJ, MD, NN Staple Codes

Specifications for SN60MC KJ, MD, NN staple codes, including length and diameter.

Technical Specifications Summary

Summary of technical specifications for SN70 and SN60MC tools, including pressure, consumption, and weight.

Model Series Technical Specifications

FramePro 601;701 XP;721 Specs

Technical specifications for FramePro 601, 701XP, and 721 models.

FramePro 602;702 XP FRH Series Specs

Technical specifications for FramePro 602/702XP FRH series models.

FramePro 651;751 XP CH Series Specs

Technical specifications for FramePro 651/751XP CH series models.

FramePro 752 XP FRH Series Specs

Technical specifications for FramePro 752XP FRH series models.

Tool Options and Accessories

Restrictive Trigger Feature

Feature helpful for precise fastener placement.

Accessory and Carrying Case Information

FramePro 600;700 CH Series Carrying Case

Durable carrying case to protect tool and accessories.

SN60 MC Hanger Attachment

Modify cap to attach a hanger using a tap and eyebolt.

SENCO Tool Accessories Line

Full line of accessories including air compressors, hoses, fittings, and safety gear.

Limited Warranty Information

Warranty Coverage for Tool Types

Warranty periods for Pneumatic, Duraspin, Fusion, Combo Kit, and GasTools.

Warranty Claim and Registration Process

Requires dated sales receipt, warranty registration, and return to authorized center.

Warranty Exclusions and General Conditions

Excludes normal wear parts, misuse, accidents; requires proper air pressure and maintenance.

Natural Disaster Replacement Policy

SENCO replaces tools destroyed by Acts of God if registered and documented.

Summary

Framing Nailer Operating Instructions

Employer Responsibilities

Safe Tool Handling and Operation

Review Safety Instructions Manual

Must read and understand the 'SAFETY INSTRUCTIONS' manual before using the tool.

Proper Tool Pointing and Air Connection

Always point the tool away from yourself and others, and connect air to the tool.

Avoid Using Damaged Tools

Never use a tool that has air leaks or requires repair.

Tool Use and Loading Procedures

SN70 Nail Guide Installation

Install the Nail Guide (GC0631) for nails shorter than 2 1/2 inches.

FramePro Loading Instructions

Insert nails into magazine, use genuine SENCO fasteners, do not load with safety or trigger depressed.

Contact Actuation Trigger Modes

Nails can be driven two ways: 'Trigger Fire' or 'bottom-fire' mode.

Single Sequential Trigger Operation

Nails can only be driven one way: depress safety element, then pull trigger.

Customer Satisfaction and Safety Reminder

Read the CSSR for safety information regarding Dual Action and Restrictive triggers.

SN60 MC Loading Instructions

Position Nail Guide, insert nails, use SENCO fasteners, do not load with safety or trigger depressed.

Tool Activation and Depth Adjustment

SN60 MC Tool Activation Process

Activate tool by positioning nail, depressing tool against surface, and pulling trigger.

Fastener Depth Adjustment Method

Adjust fastener depth by using a wrench or screwdriver, disconnect air supply first.

FramePro XP Depth Adjustment

Adjust FramePro XP depth using the wheel, disconnect air supply first.

Clearing Nail Jams

Disconnect air, release feeder shoe, remove fasteners, slide magazine back.

SN70 Specific Tool Use Procedures

SN70 E-Z Clear Latch Operation

Release E-Z Clear latch to open the door for clearing jams.

Clearing SN70 Jammed Fasteners

Remove jammed fastener, close door and latch, then clear guide body.

SN70 Magazine Loading and Securing

Loosen knob, pull magazine back, slide back into position, tighten knob.

Reconnecting Air Supply and Loading

Connect air supply, replace fasteners, and pull feeder shoe back.

Tool Features and Lockout Mechanism

FramePro Conversion to Non-Toenail

Convert tool for flat surface applications by adding the no-mar pad.

Exhaust Deflector Adjustment

Rotate deflector to change exhaust air direction; disconnect air supply first.

FramePro Lockout Feature

Tool prevents activation with 6 or fewer nails or when magazine is not locked.

Maintenance Procedures

Review Safety Instructions Manual

Read and understand the 'SAFETY INSTRUCTIONS' manual before using the tool.

Screw Tightness and Part Integrity

Keep all screws tight to ensure safe operation and prevent part breakage.

Daily Safety and Trigger Inspection

Inspect safety element and trigger for free movement when tool is disconnected.

Pneumatic Tool Lubrication

Apply Senco pneumatic oil to air inlet twice daily; use only recommended oil.

Daily Cleaning and Wear Inspection

Wipe tool clean daily and inspect for wear; use non-flammable cleaning solutions cautiously.

Troubleshooting Common Issues

SN70 Air Leak and Sluggish Operation

Troubleshoot air leaks near top or sluggish operation by checking supply and tightening screws.

SN70 Air Leak and Poor Return

Address air leaks near bottom or poor return by cleaning tool or tightening screws.

SN60 MC Air Leak and Sluggish Operation

Fix air leaks near top or sluggish operation by tightening screws or installing a repair kit.

SN60 MC Air Leak and Poor Return

Resolve air leaks near bottom or poor return by cleaning the tool or tightening screws.

FramePro Other Problems

For other FramePro problems, contact SENCO for assistance.

SN70 Nail Specifications

SN70 JF and GE Nail Codes

Specifications for SN70 JF and GE nail codes, including length in inches and mm.

SN70 GC, HC, HF, KC Nail Codes

Specifications for SN70 GC, HC, HF, KC nail codes, including length and diameter.

FramePro FRH Series Nail Specifications

FramePro 602;702 XP FRH Nail Codes

Specifications for FramePro 602/702XP FRH nail codes (GL, GD, HD, HL, KD, D).

FramePro 652;752 XP FRH Nail Codes

Specifications for FramePro 652/752XP FRH nail codes, including length and diameter.

FramePro CH Series Nail Specifications

FramePro 601;701 XP CH Nail Codes

Specifications for FramePro 601/701XP CH nail codes (GE, GC, HC, HE, H, KC, C).

FramePro 651;751 XP CH Nail Codes

Specifications for FramePro 651/751XP CH nail codes, including length and diameter.

SN60 MC Staple Specifications

SN60 MC KJ, MD, NN Staple Codes

Specifications for SN60MC KJ, MD, NN staple codes, including length and diameter.

Technical Specifications Summary

Summary of technical specifications for SN70 and SN60MC tools, including pressure, consumption, and weight.

Model Series Technical Specifications

FramePro 601;701 XP;721 Specs

Technical specifications for FramePro 601, 701XP, and 721 models.

FramePro 602;702 XP FRH Series Specs

Technical specifications for FramePro 602/702XP FRH series models.

FramePro 651;751 XP CH Series Specs

Technical specifications for FramePro 651/751XP CH series models.

FramePro 752 XP FRH Series Specs

Technical specifications for FramePro 752XP FRH series models.

Tool Options and Accessories

Restrictive Trigger Feature

Feature helpful for precise fastener placement.

Accessory and Carrying Case Information

FramePro 600;700 CH Series Carrying Case

Durable carrying case to protect tool and accessories.

SN60 MC Hanger Attachment

Modify cap to attach a hanger using a tap and eyebolt.

SENCO Tool Accessories Line

Full line of accessories including air compressors, hoses, fittings, and safety gear.

Limited Warranty Information

Warranty Coverage for Tool Types

Warranty periods for Pneumatic, Duraspin, Fusion, Combo Kit, and GasTools.

Warranty Claim and Registration Process

Requires dated sales receipt, warranty registration, and return to authorized center.

Warranty Exclusions and General Conditions

Excludes normal wear parts, misuse, accidents; requires proper air pressure and maintenance.

Natural Disaster Replacement Policy

SENCO replaces tools destroyed by Acts of God if registered and documented.

Senco FramePro 651 Specifications

General IconGeneral
TypeFraming Nailer
Power SourcePneumatic
Operating Pressure70-120 PSI
Nail Angle21 Degrees
Fastener TypeNails
Nail Size2" to 3-1/2"
Nail Gauge0.113" to 0.131"
Magazine Capacity60
Firing ModeSequential
Length12.5 inches

Related product manuals