Operating Instructions
SFT10XP
Fine Wire Stapler

Questions and Answers

  • A
    amy30Jul 27, 2025
    How to fix air leak near top of Senco SFT10XP Staple Gun?
    • V
      Valerie ThompsonJul 27, 2025
      If your Senco Staple Gun has an air leak near the top or is operating sluggishly, try tightening the screws. Also, check the air supply or install Part Kit A (YK0322).
  • R
    Raymond BrewerAug 9, 2025
    What to do if Senco Staple Gun has air leak near bottom?
    • J
      Joseph CookAug 9, 2025
      If you notice an air leak near the bottom of your Senco Staple Gun or it's not returning properly, try tightening the screws. Alternatively, clean the tool or install Part Kit B (YK0321).

Summary

Employers Responsibilities

Safety Warnings

General & Personal Safety

Read manual, use safety equipment, stay alert, avoid hazardous environments, and handle tool responsibly.

Safe Operation & Fastening

Keep finger off trigger, point away from others, drive fasteners correctly, and avoid edges/angles.

Tool Condition & Maintenance

Ensure tool integrity, use correct parts, maintain air supply, and disconnect air for maintenance.

Specific Precautions & Labels

Use proper couplings, don't load with trigger depressed, ensure labels are present, and maintain balance.

Tool Use

Loading the Stapler

Instructions for loading staples, including latch operation and rail closure.

Connecting Air and Driving Fasteners

Steps to connect air supply, position tool, and pull trigger to drive fasteners.

Operation Precautions

Note on workpiece contact absence and caution regarding trigger operation.

Clearing Staple Jams

Step-by-step guide to disconnect air, open magazine, and remove jammed fasteners.

Drive Rate Adjustment

Details on adjusting drive rate using the adjustment screw and trigger operation modes.

Maintenance

General Maintenance Warnings

Warning about qualified personnel, referencing safety warnings, and ensuring screw tightness.

Daily Checks and Lubrication

Inspect trigger movement daily and lubricate air inlet with specified oil.

Cleaning and Care

Wipe tool clean, inspect for wear, use non-flammable solutions, and avoid soaking.

Troubleshooting

Air Leak Issues

Diagnosing and resolving air leaks near the top or bottom of the tool.

Other Problems

Guidance for resolving general issues by contacting SENCO.

Accessories

Technical Specifications

Fastener Specifications

Senco SFT10XP Specifications

General IconGeneral
TypePneumatic Stapler
Power SourceAir
Fastener Capacity100 staples
Fastener TypeStaples
Staple Gauge18 Gauge
Operating Pressure70-120 psi
Air Inlet1/4" NPT
Staple Size1/4" to 9/16"
Staple Crown1/4"