SL320005700 Ed.00 - 04-2011 - 11 _EN-
6.5. Adjusting granita consistency
The consistency of the granita may be adjusted (+/-) by means of the screw
shown in the fi gure +: thicker consistency, -: thinner consistency.
6.6. Dispensing granita
To dispense the beverage, pull the tap lever.
The adjustment may be made by hand or with the aid of a suit-
able fl at-tip screwdriver.
ALARMS
In case of probe failure, the display will show the following alarm messages:
“A1”: Tank 1 probe disconnected
“A2”: Tank 1 probe short circuit
“A3”: Tank 2 probe disconnected
“A4”: Tank 2 probe short circuit
“A5”: Tank 3 probe disconnected
“A6”: Tank 3 probe short circuit
During operation, the electronic thermostat shows the temperature of the prod-
uct in the tanks, cyclically showing the temperature of the product fi rst in one
tank and then in the other, every 3 seconds.
To see which tank is referred to with the temperature reading, it is necessary to
check which decimal point is being shown.
If the decimal point viewed is on the left, the temperature reading refers to the
tank 1 (see Fig.2 Page 4).
If the decimal point viewed is in the centre, the temperature reading refers to the
tank 2 (see Fig.2, Page 4).
If the decimal point viewed is on the right, the temperature reading refers to the
tank 3 (see Fig.2, Page 4).
Fig.18
2 TANKS
Fig.19
3 TANKS
Fig.17
Note: If while using machine, the electronic thermostat should
switch off suddenly, to start it again press the . key. If the
electronic thermostat should not switch on again, switch off the
machine and contact your nearest assistance centre.
Important: While using the machine, the electronic thermostat
must always be on so as to show the temperature of the product
in the tanks.
Check the temperature of the product in the hopper on a regular
basis, using a sample thermometer to make sure that the product
remains always under the storage temperature. For machine mod-
els equipped with temperature display, also check that the tem-
perature of the product, as measured by a sample thermometer,
corresponds to the temperature shown on the machine. If there
Fig.20
Fig.21