PROGRAMMING THE SOLASTAT™, CONTINUED
Adjust the
PUMP ON
Temperature
The PUMP ON temperature determines the temperature of the tank that will
activate the pump, to transfer water into the hot water cylinder.
The Standard Value is 12°C (53.6°F), and the range is 2°C – 21°C (35.6°F –
69.8°F)
It is always set to a higher level than the PUMP Off temperature.
Note: Further information on PUMP ON Settings is included on pages 16- 17
under About the Pump Settings.
The next four
programmed
values
The next four programmed values – Holdoff Timer, Reheat Lower, Reheat
Upper and BioSafe are not operational in this model.
To bypass these values, you need to press NEXT four times to move on
through each of these to the next programmable value – Topout
Temperature.
Continued on next page
Adjust the PUMP ON value using the + and – keys. Then press NEXT to programme the next value.
The Display will flash ‘12’ to
show the PUMP ON value in
°C.