14
insulated cloth.
Repeat this procedure 2 to 3 times until the griddle has a slick surface.
LIGHTING AND SHUTTING DOWN PILOTS
All adjustment procedures associated with pilot lighting must be performed by an
authorized SERV-WARE installation or service person.
GRIDDLE TOP BURNERS (optional models)
1. Turn main gas supply ON.
2. Wait 30 seconds and, using a taper, light the hot top or griddle top pilot
3. If pilot fails to light, turn main gas supply OFF. Wait 5 minutes and repeat the
above procedures.
4. Turn one hot top or griddle top burner valve ON to remove air from the gas line.
Turn burner valve OFF when gas begins to flow.
Nightly Shutdown
1. Turn burner valve OFF; pilot will remain lit.
Complete Shutdown
1. Turn burner valve OFF; pilot will remain lit.
2. Turn main gas supply OFF.
OPEN TOP BURNERS
1. Turn main gas supply ON.
2. Wait 30 seconds and, using a taper, light the open top pilot
3. If pilot fails to light, turn main gas supply OFF. Wait 5 minutes and repeat the
above procedures.
4. Turn one open top burner valve ON to remove air from the gas line. Turn burner
OFF when gas begins to flow.
Nightly Shutdown
1. Turn burner valve OFF; pilot will remain lit.
Complete Shutdown
1. Turn burner valve OFF; pilot will remain lit.
2. Turn main gas supply OFF.