EasyManua.ls Logo

SEW-Eurodrive MOVIMOT flexible MMF3 C/DBC Series - Page 171

SEW-Eurodrive MOVIMOT flexible  MMF3 C/DBC Series
368 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
Operation
Binary control
Operating Instructions – MOVIMOT
®
flexible
171
7.2.2 Configuration 1: CW, CCW, setpoint changeover
Fixed setpoint processing mode: Mechanical setting elements
(cannot be changed)
Configuration 1 is active in Easy mode and in the delivery state.
Behavior of the drive unit Digital input "DRIVE"
LED
DI01 DI02 DI03 DI04
Right Left Poten-
tiometer
f2
Reset
The drive unit stops with deceleration setpoint t1.
1)
FCB01 Output stage inhibit is activated afterwards.
0 0 x x Lights up
yellow
The drive unit operates in positive direction of rotation
(clockwise rotation) with speed setpoint f1.
2)
The acceleration setpoint t1 is active.
1)
1 0 0 x Illuminated
in green
The drive unit is running in negative direction of rotation
(counterclockwise rotation) with the speed setpoint f1.
The acceleration setpoint t1 is active.
1)
0 1 0 x Illuminated
in green
The drive unit is running in positive direction of rotation
(clockwise rotation) with speed setpointf2.
The acceleration setpoint t1 is active.
1)
1 0 1 x Illuminated
in green
The drive unit is running in negative direction of rotation
(counterclockwise rotation) with the speed setpointf2.
The acceleration setpoint t1 is active.
1)
0 1 1 x Illuminated
in green
The drive unit stops with deceleration setpointt1.
1)
After that, FCB02 Stop default is activated.
1 1 x x Flashing
green
The drive unit is in fault state. x x x x Lights up
or flashes
red
The fault state has been reset. 0 0 0 1 Lights up
yellow
1) If potentiometer t1 is deactivated using the parameter settings, the acceleration setpoint 1/ deceleration setpoint 1 of the fixed set-
point processing will be activated.
2) If DIP switch S2/2 (Analog setpoint selection) is set to "ON", the speed setpoint of analog input AI1 is used instead of speed setpoint
f1.
0 = No voltage 1 = 24V x = Any
29129451/EN – 12/2019

Table of Contents