Fault messages with parameterizable response
Operating Instructions – MOVIMOT
®
flexible
193
Fault Description Index
no.
Possible fault response
External synchronization Here you can set the device re-
sponse to loss of external synchro-
nization.
8622.7
No response
Warning
Application stop (with out-
put stage inhibit)
Emergency stop (with out-
put stage inhibit)
Inhibit output stage
Warning with self-reset
Application stop (with out-
put stage inhibit) with self-
reset
Emergency stop (with out-
put stage inhibit) with self-
reset
Inhibit output stage with self
reset
Motor temperature pre-
warning – current para-
meter set
Motor temperature current para-
meter set – prewarning.
8442.5
No response
Warning
Application stop (with out-
put stage inhibit)
Emergency stop (with out-
put stage inhibit)
Inhibit output stage
Electromechanical capa-
city utilization – prewarn-
ing
Here you can set the device re-
sponse to an exceeded prewarning
threshold for electromechanical ca-
pacity utilization (index 8336.2).
8622.10
No response
Warning
Application stop (with out-
put stage inhibit)
Emergency stop (with out-
put stage inhibit)
Inhibit output stage
HW limit switches – cur-
rent parameter set
8572.1
No response
Emergency stop (with out-
put stage inhibit)
Emergency stop (with out-
put stage inhibit) with self-
reset
SW limit switches – cur-
rent parameter set
8572.2
No response
Emergency stop (with out-
put stage inhibit)
Emergency stop (with out-
put stage inhibit) with self-
reset