EasyManua.ls Logo

SEW-Eurodrive MOVIMOT flexible MMF3 C/DBC Series - Page 197

SEW-Eurodrive MOVIMOT flexible  MMF3 C/DBC Series
368 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
Service
Description of status and operating displays
Operating Instructions – MOVIMOT
®
flexible
197
LED Operating status/ Meaning Measure
Fault
code
Subfault code
Red
Flashes 1Hz
3 1 Ground fault Consult the “Fault
table” chapter for
possible measures
to be taken.
4 1 Brake chopper fault
6 1 Line fault
7 1 DC link fault
8 1, 2, 3 Speed monitoring fault
9 1, 2, 5, 6, 9, 10 Control mode fault
10 1, 3–11 Data Flexibility fault
11 1–6 Temperature monitoring fault
12 1, 2 Brake fault
13 5, 24 Encoder 1 fault
16 5–8, 10, 20–27 Startup fault
19 1–9 Process data fault
20 2, 11 Device monitoring fault
23 4 Power section fault
25 2–7, 20, 21, 30, 31,
61, 70
Parameter memory monitoring
26 1, 3 External fault
28 1–12, 14 FCB drive function fault
29 1–4 Hardware limit switch fault
30 1–3 Software limit switch fault
31 1–4, 7, 9 Thermal motor protection fault
32 2–6, 12 Communication fault
33 11, 12, 13 System initialization fault
34 1 Process data configuration
fault
35 1–5 Function activation fault
42 1–3 Lag fault
44 2, 3, 4 Fault
overcurrent phase U, V, W
46 2, 3, 50, 51, 52 Safety card fault
51 1 Analog processing fault
29129451/EN – 12/2019