EasyManua.ls Logo

SEW-Eurodrive MOVIMOT flexible MMF3 C/DBC Series - Page 228

SEW-Eurodrive MOVIMOT flexible  MMF3 C/DBC Series
368 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
Service
Fault/error table
Operating Instructions – MOVIMOT
®
flexible
228
8.6.18 Fault 23 Power section
Subfault: 23.1
Description: Warning
Response: Warning with self-reset
Cause Measure
Power section fault with fault response of the type
"Warning".
See also "Power section subcomponent" fault
status.
Subfault: 23.2
Description: Fault
Response: Emergency stop + output stage inhibit
Cause Measure
Power section fault with fault response of the type
"Standard".
See also "Power section subcomponent" fault
status.
Subfault: 23.3
Description: Critical fault
Response: Output stage inhibit
Cause Measure
Power section fault with fault response of the type
"Critical fault".
See also "Power section subcomponent" fault
status.
Subfault: 23.4
Description: Hardware fault
Response: Output stage inhibit
Cause Measure
A fault occurred in a hardware component of the
power section, e.g.: Overcurrent hardware com-
parator.
– Check the current supply.
– Increase the ramp time.
– Check for correct motor size (the motor current
is too high).
– Contact SEW‑EURODRIVE Service.
Switched-mode power supply fault, hardware
fault.
– Check the current supply.
– Check the DC24V supply voltage.
Fault at the gate driver of an IGBT. Defect in the power output stage. Contact the
SEW‑EURODRIVE Service.
Invalid process data configuration. Status of con-
trol section and power section are not compatible.
Contact the SEW‑EURODRIVE Service.
Subfault: 23.5
Description: Invalid process data configuration
Response: Output stage inhibit
Cause Measure
Invalid process data configuration. Contact the SEW‑EURODRIVE Service.