EasyManua.ls Logo

Sewha SI 550 - Behind of the SI550

Sewha SI 550
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 10 -
SI 510 WEIGHING INDICATOR
3-4. Behind of the SI550
`
(1) AC Power input terminal
(2) External input terminal: User selectable 6EA
(3) Serial Interface terminal
Terminal
RxD
TxD
GND
C/L
C/L
RS – 232
Rx
Tx
GND
C/L
C/L
(4) Loadcell Input terminal
Terminal
EXC+
EXC-
SIG+
SIG-
SHLD
Loadcell
EXC+
EXC-
SIG+
SIG-
SHEILD
(5) Relay output terminal: User selectable 7EA (Function 141~147), COM is common.
Terminal
O1
O2
O3
O4
O5
O6
O7
OC
Relay
output
RELAY 1
RELAY 2
RELAY 3
RELAY 4
RELAY 5
RELAY 6
RELAY 7
RELAY
COM
(6) Analog output terminal
Terminal
-
+
Remark
4~20mA
(-)
(+)
Option
0~10V
(-)
(+)
Option
(7) Option serial interface terminal
Terminal
1
2
3
4
Remark
RS – 232C
GND
GND
Rx
Tx
Option
RS - 422
TxD-
TxD+
RxD-
RxD+
Option
RS - 485
Unused
Unused
D-
D+
Option
Please check the Comm. and other specification in the label, attached on the cover
plate first, and make connection according to that information.
(3)Serial I/F
(4)Loadcell Input
(1)Power
(5) Relay output
(2) External