In battery-operated mode, the regeneration is not carried out and the parameters cannot
be edited.
4.5 Microswitch search
When powering the module may sometimes display F1-| or F2-| where the number
indicates if we are carrying out the first or the second microswitch search attempt, a
turning bar is also shown to indicate that the motor is on. If both searches fail, the
message FR01 is displayed.
4.6 Salt recharge
The controller has a counter that is decreased by one at each regeneration. When the
counter reaches 0, a salt alarm is generated. To recharge the counter to the initial value
of the parameter SA, press and hold when the module is in service, āSALā will flash on
the display for 5 seconds and the counter will be reset to the value setup.
4.7 Statistics menu
The Statistics menu displays some historical data of the module. To open the Statistics
menu, press and hold for 5 seconds.
The following data are displayed:
Data Description
Xxxx Number of regenerations carried out
SAxx Number of residual regenerations before the salt alarm is generated.
FFxx Number of days elapsed since the last regeneration.
Lxxxxxx Overall volume treated (in litres).
Xx:xx Day and time of the last regeneration carried out, the regeneration icon is on.
Xx:xx Day and time of the second last regeneration carried out, the service icon is on.
Xx:xx
Day and time of the third last regeneration carried out service and regeneration icons are on simultaneously.
End End of the statistics.
189x Software release and revision.
Battery-operated status
25